Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Design Example: Deciding Thickness of Lubricating Fluid in a Shaft01:23

Design Example: Deciding Thickness of Lubricating Fluid in a Shaft

283
Effective lubrication between a rotating shaft and its bearing housing is essential in rotating machinery to minimize friction, wear, and energy loss. With carefully controlled thickness and viscosity, the lubricant layer prevents metal-to-metal contact, ensuring smooth operation.
To calculate the required thickness of the lubricant layer, the tangential velocity at the shaft's surface must first be determined. This velocity is calculated by converting the rotational speed to angular velocity...
283
Design of Transmission Shafts01:16

Design of Transmission Shafts

677
The design of a transmission shaft is governed by two primary specifications: the power it transmits and its rotational speed. These parameters guide the selection of the shaft's material and cross-sectional dimensions, ensuring that the material's maximum shearing stress remains within the elastic limit while transmitting the desired power at the given speed. The system's power is intrinsically linked to the applied torque. The torque applied to the shaft can be calculated by reconfiguring the...
677
Transmission Shafts: Problem Solving01:09

Transmission Shafts: Problem Solving

453
Designing a solid shaft that transmits power from a motor to a machine tool involves a series of calculations to ensure the shaft can withstand the stresses applied by bending moments and torques. First, calculate the torque exerted on the gear, considering the power transmitted by the shaft and its rotational speed. Following this, compute the tangential forces acting on the gears, which directly relate to the torque and the gear radius.
Next, use bending moment diagrams for the shaft to...
453
Design of Transmission Shafts - Stress Analysis01:15

Design of Transmission Shafts - Stress Analysis

685
Designing a transmission shaft requires a thorough understanding of the stresses induced by bending moments and torques, especially in systems where power is transferred through gears. These forces create force-couple systems at the centers of the shaft's cross-sections, leading to both transverse and torsional loading. Although shearing stresses from transverse loads are typically smaller than those from torques and are often overlooked, the significant normal stresses from these loads...
685
Design Example: Flow of Oil Through Circular Pipes01:25

Design Example: Flow of Oil Through Circular Pipes

381
Understanding fluid flow behavior through pipes is critical in fluid mechanics, especially in applications like oil transportation through pipelines. Hagen-Poiseuille's law provides an exact solution derived from the Navier-Stokes equations for steady, incompressible, and laminar flow within a circular pipe. Hagen-Poiseuille's law helps determine the necessary pressure drop across a pipeline section by determining parameters like pipe length, radius, oil viscosity, and the desired volumetric...
381
Design Example: Creating a Hydraulic Model of a Dam Spillway01:21

Design Example: Creating a Hydraulic Model of a Dam Spillway

617
Scaled hydraulic models of dam spillways provide a practical way to replicate and study the intricate flow dynamics of these structures. Often built to a 1:15 ratio, these models allow for observing critical water behavior, such as velocity distribution, flow patterns, and energy dissipation.
617

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Robotic Rehabilitation Using the Hybrid Assistive Limb for Drop Fingers in a Patient with Cervical Spondylotic Radiculopathy: A Case Report.

Journal of clinical medicine·2026
Same author

Shoulder-wearable soft robot for assisting older adults in scapular stretching.

Wearable technologies·2026
Same author

Hybrid Assistive Limb Single Joint Type (HAL-SJ) Training for Knee Osteoarthritis: A Case Series.

Cureus·2026
Same author

A Waist-Mounted Interface for Mobile Viewpoint-Height Transformation Affecting Spatial Perception.

Sensors (Basel, Switzerland)·2026
Same author

Passive Add-On Mechanism with Rotational Dampers for Step-Down Support in Electric Wheelchairs.

Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference·2025
Same author

Spinal Disease Classification Using Deep Learning on Dual-View Videos.

Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference·2025

Related Experiment Video

Updated: Dec 30, 2025

Design and Implementation of a Bespoke Robotic Manipulator for Extra-corporeal Ultrasound
07:41

Design and Implementation of a Bespoke Robotic Manipulator for Extra-corporeal Ultrasound

Published on: January 7, 2019

9.5K

Optimized Design of a Variable Viscosity Link for Robotic AFO.

Modar Hassan, Keisuke Yagi, Hideki Kadone

    Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference
    |January 18, 2020
    PubMed
    Summary

    A new Ankle Foot Orthosis (AFO) improves ankle support for foot-drop. It uses an elastic mechanism to prevent foot-slap and aids toe lift, enhancing walking ability for individuals with foot-drop symptoms.

    More Related Videos

    Design and Fabrication of an Elastomeric Unit for Soft Modular Robots in Minimally Invasive Surgery
    11:06

    Design and Fabrication of an Elastomeric Unit for Soft Modular Robots in Minimally Invasive Surgery

    Published on: November 14, 2015

    9.3K
    A Modeling and Simulation Method for Preliminary Design of an Electro-Variable Displacement Pump
    09:04

    A Modeling and Simulation Method for Preliminary Design of an Electro-Variable Displacement Pump

    Published on: June 1, 2022

    3.5K

    Related Experiment Videos

    Last Updated: Dec 30, 2025

    Design and Implementation of a Bespoke Robotic Manipulator for Extra-corporeal Ultrasound
    07:41

    Design and Implementation of a Bespoke Robotic Manipulator for Extra-corporeal Ultrasound

    Published on: January 7, 2019

    9.5K
    Design and Fabrication of an Elastomeric Unit for Soft Modular Robots in Minimally Invasive Surgery
    11:06

    Design and Fabrication of an Elastomeric Unit for Soft Modular Robots in Minimally Invasive Surgery

    Published on: November 14, 2015

    9.3K
    A Modeling and Simulation Method for Preliminary Design of an Electro-Variable Displacement Pump
    09:04

    A Modeling and Simulation Method for Preliminary Design of an Electro-Variable Displacement Pump

    Published on: June 1, 2022

    3.5K

    Area of Science:

    • Biomedical Engineering
    • Rehabilitation Technology
    • Biomechanics

    Background:

    • Foot-drop symptoms significantly impair gait, leading to challenges like foot-slap and toe-drag.
    • Existing Ankle Foot Orthoses (AFOs) may not fully address the dynamic requirements of gait support.
    • Novel orthotic designs are needed to improve mobility and reduce fall risk in affected individuals.

    Purpose of the Study:

    • To develop and evaluate a novel Ankle Foot Orthosis (AFO) designed for comprehensive gait support in individuals with foot-drop.
    • To enhance the braking-holding power of the elastic link mechanism and analyze its torque-angle characteristics.
    • To pilot test the AFO's efficacy in mitigating foot-slap and toe-drag during walking.

    Main Methods:

    • Development of a novel AFO incorporating an elastic link mechanism for braking and an energy store-and-release system for toe lift.
    • Improvement of the elastic link mechanism's braking-holding power compared to previous iterations.
    • Characterization of the AFO's torque-angle properties with the updated mechanism.
    • Conducting a pilot study with a single participant exhibiting foot-drop symptoms.

    Main Results:

    • The improved elastic link mechanism demonstrated enhanced braking-holding power.
    • The developed AFO exhibited specific torque-angle characteristics suitable for gait support.
    • Pilot testing indicated the AFO's potential to mitigate foot-slap and toe-drag, supporting proposed functions.

    Conclusions:

    • The novel AFO with an improved elastic link mechanism shows promise for supporting gait in individuals with foot-drop.
    • The device effectively addresses key gait deviations, including foot-slap and toe-drag.
    • Further clinical validation is warranted to confirm the AFO's long-term benefits and effectiveness across a broader patient population.