The Cuffless Blood Pressure Measurement with Multi-dimension Regression Model based on Characteristics of Pulse
Abstract:
According to the advancement of wearable technology, many physiological monitoring instruments are gradually converted into wearable devices. But, the blood pressure monitor still is a cuff-type device in the consumer market, which also does not do the beat-by-beat continuous blood pressure measurement. Now, the cuffless blood pressure measurement has been developed based on the pulse transit time (PTT) but its accuracy is not better. According to the cardiac hemodynamic theorem, the blood pressure relates with the arterial characteristics. Therefore, the purpose of this study was to use the characteristics of the pulse wave measured by photoplethysmography (PPG) to estimate the blood pressure with a multi-dimension regression model. The contour of pulse wave includes some characteristics of the artery. There were 10 subjects participating the experiment, and the blood pressure of the subject was changed by the exercise. The results showed that the cumulate root mean square error of the estimated systolic and diastolic pressures with the multi-parameters were 69.3 mmHg and 39.8 mmHg were better than only using one parameter, PTT, 82.1 mmHg and 45.2 mmHg, respectively.
More Related Videos
Related Concept Videos
Measurement of Blood Pressure
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Assessment of blood pressure in brachial artery(two-step method)
Sites for measruring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...