Related Experiment Video
Updated: Dec 30, 2025

A Duplex Digital PCR Assay for Simultaneous Quantification of the Enterococcus spp. and the Human Fecal-associated HF183 Marker in Waters
Published on: March 9, 2016
Trace Analysis of 61 Emerging Br-, Cl-, and I-DBPs: New Methods to Achieve Part-Per-Trillion Quantification in
Amy A Cuthbertson1, Hannah K Liberatore1, Susana Y Kimura1,2
1Department of Chemistry and Biochemistry , University of South Carolina , Columbia , South Carolina 29208 , United States.
Abstract:
Disinfection byproducts (DBPs) are a ubiquitous source of chemical exposure in drinking water and have been associated with serious health impacts in human epidemiologic studies. While toxicology studies have pinpointed DBPs with the greatest toxic potency, analytical methods have been lacking for quantifying complete classes of most toxic DBPs at sufficiently low quantification limits (ng/L). This new method reports the parts-per-trillion quantification for 61 toxicologically significant DBPs from 7 different chemical classes, including unregulated iodinated haloacetic acids (HAAs) and trihalomethanes (THMs), haloacetaldehydes, haloketones, haloacetonitriles, halonitromethanes, and haloacetamides, in addition to regulated HAAs and THMs. The final optimized method uses salt-assisted liquid-liquid extraction in a single extraction method for a wide range of DBPs, producing the lowest method detection limits to-date for many compounds, including highly toxic iodinated, brominated, and nitrogen-containing DBPs. Extracts were divided for the analysis of the HAAs (including iodinated HAAs) by diazomethane derivatization and analysis using a GC-triple quadrupole mass spectrometer with multiple reaction monitoring, resulting in higher signal-to-noise ratios, greater selectivity, and improved detection of these compounds. The remaining DBPs were analyzed using a GC-single quadrupole mass spectrometer with selected ion monitoring, utilizing a multimode inlet allowed for lower injection temperatures to allow the analysis of thermally labile DBPs. Finally, the use of a specialty-phase GC column (Restek Rtx-200) significantly improved peak shapes, which improved separations and lowered detection limits. Method detection limits for most DBPs were between 15 and 100 ng/L, and relative standard deviations in tap water samples were mostly between 0.2 and 30%. DBP concentrations in real samples ranged from 40 to 17 760 ng/L for this study.
More Related Videos
11:19Preparation and Testing of Impedance-based Fluidic Biochips with RTgill-W1 Cells for Rapid Evaluation of Drinking Water Samples for Toxicity
Published on: March 7, 2016
12:11A Modified EPA Method 1623 that Uses Tangential Flow Hollow-fiber Ultrafiltration and Heat Dissociation Steps to Detect Waterborne Cryptosporidium and Giardia spp.
Published on: July 9, 2012