Direct Electrochemical Sensing of Phosphate in Aqueous Solutions Based on Phase Transition of Calcium Phosphate

Shuquan Sun1, Qixuan Chen1, Sujitraj Sheth1

  • 1School of Chemical and Material Engineering , Jiangnan University , 1800 Lihu Road , Wuxi , Jiangsu Province 214122 , P. R. China.

ACS Sensors
|January 18, 2020
PubMed

Related Concept Videos

Potentiometry: Membrane Electrodes01:15

Potentiometry: Membrane Electrodes

Membrane electrodes, also known as p-ion electrodes, use membranes that selectively interact with free analyte ions, generating a potential difference across the membrane. The resulting membrane potential, known as the asymmetry potential, is not zero even when analyte concentrations on both sides of the membrane are equal. The membrane's response is typically not selective to a single analyte but proportional to the concentration of all ions in the sample solution capable of interacting at...
1.5K
Roles of Electrolytes: Calcium and Phosphate01:27

Roles of Electrolytes: Calcium and Phosphate

Calcium and phosphate are essential electrolytes in the human body, with calcium being the most abundant mineral. Around 99% of the body's calcium is stored in the skeleton and teeth, forming a crystal lattice of mineral salts in combination with phosphates. Calcium plays crucial roles in various bodily functions such as blood clotting, neurotransmitter release, muscle tone maintenance, and nervous and muscle tissue excitability.
The calcium concentration in blood plasma is primarily...
1.0K
Factors Affecting Solubility04:01

Factors Affecting Solubility

Compared with pure water, the solubility of an ionic compound is less in aqueous solutions containing a common ion (one also produced by dissolution of the ionic compound). This is an example of a phenomenon known as the common ion effect, which is a consequence of the law of mass action that may be explained using Le Chȃtelier’s principle. Consider the dissolution of silver iodide:
36.4K
Controlled-Potential Coulometry: Electrolytic Methods01:17

Controlled-Potential Coulometry: Electrolytic Methods

Controlled-potential coulometry, also known as potentiostatic coulometry, employs a three-electrode system in which the working electrode's potential is precisely regulated using a potentiostat. Platinum working electrodes are utilized for positive potentials, while mercury pool electrodes are favored for extremely negative potentials. The platinum counter electrode is separated from the analyte using a membrane or salt bridge to avoid interference in the analysis.
The chosen potential...
583
Phosphate Buffer01:22

Phosphate Buffer

The phosphate buffer system is a critical biological mechanism for maintaining pH stability in the body. This system operates primarily through two components: sodium dihydrogen phosphate (NaH2PO4), which acts as a weak acid, and sodium hydrogen phosphate (Na2HPO4), which serves as a weak base.
Sodium dihydrogen phosphate does not fully dissociate in neutral or acidic solutions. When a strong base, such as sodium hydroxide (NaOH), is introduced into the solution, sodium dihydrogen phosphate...
4.6K