Cardiac-Neurovascular Adverse Effects Responsible to Contrast Transcranial Doppler: A Case Report
Xiuyun Mo1, Zhengzheng Xuan1, Weijun Zhang1
1Department of Comprehensive Stroke Center, The Second Affiliated Hospital of Guangzhou University of Chinese Medicine, Guangzhou, China.
Introduction and Case Presentation: A 44-year-old female patient suffered migraines and underwent contrast-enhanced transcranial Doppler (c-TCD). During the rapid injection of contrast agent, she suffered chest tightness, palpitation, decreased consciousness, perimouth numbness, and headache, respectively. Meanwhile, "curtain" pattern of air embolic signals lasted up to 115 seconds in her decreased right middle cerebral artery accompanied with arrhythmia. The microair embolic signals lasted as long as 340 seconds. The patient's symptoms were relieved in 30 minutes. The aforementioned symptoms and signs occurred, lasted, then disappeared coinciding in time with changes of microbubbles. The woman was later found to have ventricular septal defect. Discussion: The adverse effects to cardiac-neurovascular system of c-TCD are reported for the first time, which arouse attention to safety of the procedure.
Introduction and Case Presentation: A 44-year-old female patient suffered migraines and underwent contrast-enhanced transcranial Doppler (c-TCD). During the rapid injection of contrast agent, she suffered chest tightness, palpitation, decreased consciousness, perimouth numbness, and headache, respectively. Meanwhile, "curtain" pattern of air embolic signals lasted up to 115 seconds in her decreased right middle cerebral artery accompanied with arrhythmia. The microair embolic signals lasted as long as 340 seconds. The patient's symptoms were relieved in 30 minutes. The aforementioned symptoms and signs occurred, lasted, then disappeared coinciding in time with changes of microbubbles. The woman was later found to have ventricular septal defect. Discussion: The adverse effects to cardiac-neurovascular system of c-TCD are reported for the first time, which arouse attention to safety of the procedure.
Related Concept Videos
Imaging Studies for Cardiovascular System V: CT
Imaging Studies for Cardiovascular System IV: CMRI
Cardiac Catheterization IV: Nursing Management
Imaging Studies VII: Vascular Imaging
Imaging Studies III: Computed Tomography