Related Experiment Video
Updated: Dec 30, 2025

The Rigid Tube as an Alternative in Controlling the Problematic Airway
Published on: June 6, 2020
Patient factors associated with difficult flexible bronchoscopic intubation under general anesthesia: a prospective
Taher Touré1, Stephan R Williams2, Mahmoud Kerouch1
1Département d'anesthésiologie, Centre hospitalier de l'Université de Montréal, Montréal, QC, Canada.
Purpose:
Patient characteristics associated with difficult tracheal intubation using a flexible bronchoscope (FB) under general anesthesia have not been prospectively evaluated. This observational study aimed to identify demographic and morphologic factors associated with difficult FB intubation.
Methods:
We recruited 420 adult elective surgery patients undergoing tracheal intubation during general anesthesia. Patients characteristics were recorded including age, sex, weight, height, body mass index, American Society of Anesthesiologists physical status, history of snoring, obstructive sleep apnea, Mallampati score, upper lip bite test score, neck circumference and skinfold thickness, maximal neck flexion and extension angles, absence of teeth, Cormack and Lehane grade, presence of blood or secretions during intubation, as well as the inter-incisor, thyromental, sternothyroid, and manubriomental distances. The time (duration) needed to complete intubation (primary endpoint) and the number of attempts needed were correlated with these patient characteristics in a multivariable analysis.
Results:
Intubation was successful on the first attempt in 409/420 patients (97%). Seven patients (1.7%) needed more than one attempt. Failure to intubate with the FB occurred in four patients (1%). A correlation was found between intubation duration and visibility impaired by secretions or blood (P < 0.001), higher neck skinfold thickness (P < 0.001), and larger endotracheal tube diameter (relative to a constant 5.5 mm FB; P < 0.001).
Conclusions:
The presence of secretions or blood that impair FB glottic visualization, a larger diameter endotracheal tube on the same size FB, as well as higher neck skinfold thickness may prolong the duration of FB intubation under general anesthesia.
Trial Registration:
www.clinicaltrials.gov (NCT02769819); registered 5 May, 2016.
More Related Videos
Related Concept Videos
Endotracheal Intubation I: Procedure
The ET tube comprises various components, including a standard adaptor to attach a bag-valve-mask (BVM) or ventilator, a cuff, a pilot balloon, and radiopaque markings along its length to measure the insertion distance. The tube sizes...
Endotracheal Intubation II: Nursing Management
1. Nursing Care of Patients Before Intubation
Before the endotracheal intubation procedure, nurses play an essential role in ensuring the process goes smoothly. The nurses must be familiar with intubation...
Cardiopulmonary Resuscitation V: Advanced Airway Management Techniques
Endotracheal Tube Extubation
Procedure
Extubation removes the endotracheal tube (ETT) from the patient on mechanical ventilation. It requires a well-coordinated, multidisciplinary approach involving physicians, nurses, respiratory therapists, and other healthcare professionals....
Inhalational Anesthetics: Overview
Endoscopic Studies I: Bronchoscopy and Thoracoscopy
Bronchoscopy
Description
Bronchoscopy is a procedure that involves direct visualization of the larynx, trachea, and bronchi for diagnostic and therapeutic purposes. A flexible fiber optic or rigid bronchoscope is used to carry out the procedure. The fiber-optic bronchoscope is more frequently used due...

