Large Scale Non-targeted Metabolomic Profiling of Serum by Ultra Performance Liquid Chromatography-Mass Spectrometry UPLC-MS
Published on: March 14, 2013
Assessing accuracy, precision and selectivity using quality controls for non-targeted analysis
Brian Ng1, Natalia Quinete2, Piero R Gardinali3
1Department of Chemistry and Biochemistry, Florida International University, Miami, FL, United States of America.
Abstract:
The benchmarks to assess reproducibility are not well defined for non-target analysis. Parameters to evaluate analytical performance, such as accuracy, precision and selectivity, are well defined for target analysis, but remain elusive for non-target screening analysis. In this study, quality control (QC) guidelines are proposed to assure reliable data in non-target screening methodologies using a simple set of standards. Workflow reproducibility was assessed using an in-house QC mixture containing selected compounds with a wide range of polarity that can be detected either by electrospray ionization (ESI) in positive or negative mode. The analysis was performed by online solid phase extraction (SPE) liquid chromatography coupled to high resolution mass spectrometry (LC-HRMS). Data processing was done by a commercially available software, Compound Discoverer v. 3.0 using an environmental working template, which searched a multitude of databases, including Chemspider, EPA Toxcast, MzCloud among others. We have specifically evaluated method specificity, precision, accuracy and reproducibility in terms of peak area and retention time variability, true positive identification rate, intraday (within days) and interday (consecutive days) variations and the use of QC samples to reduce false positives. The method showed a satisfactory accuracy with an identification rate of ≥70% for most of the QC compounds. Precision estimated based on peak area relative standard deviation (RSD) ranged between 30 and 50% for most of the compounds. Data normalization to a single internal standard did not improve peak area variability. Retention time precision showed great repeatability and reproducibility (RSD ≤ 5%). In addition, a simple model of RT vs log Kow was designed based on our QC mixtures to efficiently reduced false positives by an average of 49.1%.
More Related Videos
09:04Identifying Per- and Polyfluorinated Chemical Species with a Combined Targeted and Non-Targeted-Screening High-Resolution Mass Spectrometry Workflow
Published on: April 18, 2019
11:00Untargeted Metabolomics from Biological Sources Using Ultraperformance Liquid Chromatography-High Resolution Mass Spectrometry UPLC-HRMS
Published on: May 20, 2013
Related Concept Videos
Quality Assurance
Data Validation
Key parameters for method validation include:
Quality Control
Quality control helps track data, visualize trends, and identify variations, making it easier to detect deviations that may affect the accuracy of an analysis. One way to do this is by generating a quality control chart, which...