Relationship between Measurement Errors in Myocardial T1 Mapping and Heart Rate
Yasuo Amano1, Yuko Omori1, Fumi Yanagisawa1
1Department of Radiology, Nihon University Hospital.
Summary
Myocardial T1 mapping using Modified Look-Locker inversion recovery (MOLLI) shows more errors in patients with lower heart rates (bradycardia). Careful measurement is needed during MOLLI scans for these patients.
Area of Science:
- Cardiovascular Magnetic Resonance Imaging
- Quantitative MRI Techniques
Background:
- Modified Look-Locker inversion recovery (MOLLI) is a common technique for myocardial T1 mapping.
- While MOLLI is generally robust, especially during tachycardia, measurement errors can occur.
Purpose of the Study:
- To investigate the relationship between heart rate (HR) and measurement errors in myocardial T1 mapping using a confidence map.
- To assess if lower heart rates are associated with increased T1 mapping inaccuracies.
Main Methods:
- Sixty-nine male patients with normal native T1 values underwent 5s(3s)3s MOLLI scanning.
- Measurement errors in the septal myocardium were graded by observers using a confidence map (0-3 scale).
- Error scores were compared with instantaneous heart rate (iHR) parameters and left ventricular ejection fraction (LVEF).
Main Results:
- Patients with greater than score 1 measurement errors showed significantly lower minimum iHR compared to those with score 1 or less (49.8 ± 10.1 vs. 59.6 ± 9.7 bpm).
- Higher error scores correlated with lower minimum instantaneous heart rates during the MOLLI scan.
Conclusions:
- A confidence map can identify increased measurement errors in myocardial T1 mapping associated with lower minimum heart rates.
- Clinicians should exercise caution when interpreting myocardial T1 values obtained during MOLLI scans in patients with bradycardia.
Related Concept Videos
Errors occurring during blood pressure monitoring
1.3K
Blood pressure monitoring is a crucial clinical procedure in diagnosing and managing various cardiovascular conditions. Despite its significance, the accuracy of blood pressure measurements can be compromised by multiple factors, potentially leading to either falsely high or low readings. These inaccuracies are critical as they can significantly impact patient care. So, it is vital to understand these challenges deeply and adopt strategic approaches to minimize errors.
Several factors...
Several factors...
1.3K
Correlation between ECG and Cardiac Cycle
11.3K
The electrical signals recorded on an electrocardiogram (ECG) occur before the mechanical processes of contraction and relaxation during the cardiac cycle.
A cardiac action potential originates in the SA node and spreads throughout the atria and the AV node in approximately 0.03 seconds. This results in the P wave in an ECG and triggers atrial contraction. The action potential is then briefly slowed at the AV node, allowing the atria to contract and fill the ventricles with blood before...
A cardiac action potential originates in the SA node and spreads throughout the atria and the AV node in approximately 0.03 seconds. This results in the P wave in an ECG and triggers atrial contraction. The action potential is then briefly slowed at the AV node, allowing the atria to contract and fill the ventricles with blood before...
11.3K
Cardiac Output I:Effect of Heart Rate on Cardiac Output
2.2K
Cardiac Output
Cardiac output (CO) refers to the total amount of blood ejected by one of the ventricles in liters per minute (L/min). In a resting adult, CO ranges from 5 to 6 L/min, adjusting according to the body's metabolic requirements.
Effect of Heart Rate on Cardiac Output
Cardiac output adapts to metabolic demands during stress, physical activity, or illness. The autonomic nervous system regulates heart rate via the sinoatrial node. The parasympathetic nervous system decreases heart...
Cardiac output (CO) refers to the total amount of blood ejected by one of the ventricles in liters per minute (L/min). In a resting adult, CO ranges from 5 to 6 L/min, adjusting according to the body's metabolic requirements.
Effect of Heart Rate on Cardiac Output
Cardiac output adapts to metabolic demands during stress, physical activity, or illness. The autonomic nervous system regulates heart rate via the sinoatrial node. The parasympathetic nervous system decreases heart...
2.2K
Factors Influencing Heart Rate
6.0K
The heart rate, or pulse rate, is a vital indicator of cardiovascular health. It reflects the number of times the heart beats per minute. Various physiological and environmental factors influence heart rate, increasing or decreasing cardiac output. Understanding these factors is crucial for assessing heart function and identifying potential health issues.
Let us explore the significant factors affecting heart rate, including age, body temperature, posture, acute pain, chemical influences,...
Let us explore the significant factors affecting heart rate, including age, body temperature, posture, acute pain, chemical influences,...
6.0K