[Nationwide Survey of Medical Radiation Exposure on Cardiovascular Examinations in Japan]
Tooru Ishibashi1, Yasutaka Takei2, Hajime Sakamoto3
1Department of Radiological Technology, Tsuchiya General Hospital.
Purpose:
It is very important to manage the radiation dose of cardiovascular interventional (CVI) procedures. Overseas, the diagnostic reference levels for cardiac interventional procedures were established with the air kerma at the patient entrance reference point (Ka,r) and the air kerma-area product (PKA). Although the Japan DRLs 2015 was established by the Japan Network for Research and Information on Medical Exposure (J-RIME), the Japan DRL for CVIs were established by fluoroscopic dose rates of 20 mGy/min at the patient entrance reference point with 20 cm thickness polymethyl methacrylate (PMMA) phantom. In the present our study, we performed a questionnaire survey of indicated values of angiographic parameters in CVI procedures.
Methods:
A nationwide questionnaire was sent by post to 765 facilities. Question focused on angiographic technology, exposure parameters and radiation doses as the displayed dosimetric parameters on the angiographic machine.
Results:
The recovery rate was 22.8% at 175 out of 765 facilities. In total 1728 cases of the coronary angiography (CAG), 1703 cases of the percutaneous coronary intervention (PCI), 962 cases of the radiofrequency catheter ablation (RFCA) and 377 cases of pediatric CVI. The 75th percentile value of Ka,r, PKA, fluoroscopy time (FT) and number of cine images (CI) for CAG, PCI, RFCA and pediatric CVI were 702, 2042, 644, and 159 mGy, respectively, 59.3, 152, 81.3, and 14.9 Gy・cm2, respectively, 10.2, 35.6, 61.1, and 35.6 min, respectively and 1503, 2672, 722, and 2378 images, respectively. Our investigation showed that the angiographic parameters were different in several CVI procedures.
Conclusions:
The displayed dosimetric parameters on the angiographic machine in CVI procedures showed different values. We should classify the dosimetric parameters for each procedure.
More Related Videos
06:02Anatomical Reconstructions of the Human Cardiac Venous System using Contrast-computed Tomography of Perfusion-fixed Specimens
Published on: April 18, 2013
08:10Estimating Bilateral Atrial Function by Cardiovascular Magnetic Resonance Feature Tracking in Patients with Paroxysmal Atrial Fibrillation
Published on: July 20, 2022
Related Concept Videos
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Imaging Studies for Cardiovascular System IV: CMRI
Biological Effects of Radiation
Imaging Studies for Cardiovascular System V: CT
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...