Related Experiment Video
Updated: Dec 30, 2025

Radionuclide-fluorescence Reporter Gene Imaging to Track Tumor Progression in Rodent Tumor Models
Published on: March 13, 2018
Test-Retest Repeatability of [18F]MC225-PET in Rodents: A Tracer for Imaging of P-gp Function
Lara García-Varela1, David Vállez García1, Manuel Rodríguez-Pérez2
1Department of Nuclear Medicine and Molecular Imaging , University of Groningen, University Medical Center Groningen , Hanzeplein 1 , P.O. Box 30001, 9713 GZ Groningen , The Netherlands.
Abstract:
In longitudinal PET studies, animals are repeatedly anesthetized which may affect the repeatability of PET measurements. The aim of this study was to assess the effect of anesthesia on the P-gp function as well as the reproducibility of [18F]MC225 PET scans. Thus, dynamic PET scans with blood sampling were conducted in 13 Wistar rats. Seven animals were exposed to isoflurane anesthesia 1 week before the PET scan ("Anesthesia-exposed" PET). A second group of six animals was used to evaluate the reproducibility of measurements of P-gp function at the blood-brain barrier (BBB) with [18F]MC225. In this group, two PET scans were made with a 1 week interval ("Test" and "Retest" PET). Pharmacokinetic parameters were calculated using compartmental models and metabolite-corrected plasma as an input function. "Anesthesia-exposed" animals showed a 28% decrease in whole-brain volume of distribution (VT) (p < 0.001) compared to "Test", where the animals were not previously anesthetized. The VT at "Retest" also decreased (19%) compared to "Test" (p < 0.001). The k2 values in whole-brain were significantly increased by 18% in "Anesthesia-exposed" (p = 0.005) and by 15% in "Retest" (p = 0.008) compared to "Test". However, no significant differences were found in the influx rate constant K1, which is considered as the best parameter to measure the P-gp function. Moreover, Western Blot analysis did not find significant differences in the P-gp expression of animals not pre-exposed to anesthesia ("Test") or pre-exposed animals ("Retest"). To conclude, anesthesia may affect the brain distribution of [18F]MC225 but it does not affect the P-gp expression or function.
More Related Videos
15:10A Dual Tracer PET-MRI Protocol for the Quantitative Measure of Regional Brain Energy Substrates Uptake in the Rat
Published on: December 28, 2013
09:55Radiosynthesis, Quality Control, and Small Animal Positron Emission Tomography Imaging of 68Ga-Labelled Nano Molecules
Published on: October 4, 2024
Related Concept Videos
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...