The influence of undercut depths on the accuracy of casts poured from irreversible hydrocolloid impression materials
Related Experiment Video
Updated: Dec 30, 2025

Casting Protocols for the Production of Open Cell Aluminum Foams by the Replication Technique and the Effect on Porosity
Published on: December 11, 2014
Vidya Latchmi Mudliar1, Kai Chun Li2, Ludwig Jansen van Vuuren2
1Department of Oral Rehabilitation, School of Dentistry and Oral Health, College of Medicine, Nursing and Health Science, Fiji National University, Suva, Fiji.
Objectives:
To evaluate the elastic recovery of a typical irreversible hydrocolloid impression material in terms of the amount of undercut identified and additional thickness of spacer provided before custom tray fabrication.
Methods:
This study surveyed the undercut depths of the teeth surfaces and lingual sulci of one hundred partially dentate mandibular dental casts which were subsequently scanned and the data exported as STL files. A typical cast from each undercut category (0.5mm, 1mm, 1.5mm, 2mm, 2.5mm, 3mm, 4mm, 5mm) was 3D printed. Three custom trays were constructed with spacer thicknesses representing 20%, 30% and 50% compression against the wall of the custom trays on removal, impressions recorded, and casts fabricated in dental stone. Measurements for elastic recovery of irreversible hydrocolloid were done using an internal caliper and a digital caliper. All measurements were done by the principal investigator. Non-parametric analyses were used for comparisons of the undercut values between the 3D printed and poured casts to determine the amount of elastic recovery of the irreversible hydrocolloid impression material.
Results:
There was no statistically significant difference in measurements between the original 3D printed casts and the poured casts, irrespective of percentage compression (p 0.05).
Conclusions:
In removable partial denture construction, casts should be blocked out parallel to the path of insertion and then an additional 3mm of spacer applied as a standard technique before custom tray fabrication to ensure elastic recovery of the irreversible hydrocolloid impression.
Clinical Implications:
In severe undercut situations, accurate impressions can be taken using irreversible hydrocolloid by blocking out all undercut surfaces on the teeth and lingual sulci before adapting additional three-millimetre wax spacer on casts when constructing custom trays thereby ensuring accurate and reliable impressions for removable prosthesis construction.
Related Concept Videos
Porosity in Cement Paste
The balance of water to cement in the mix is...
Impact Strength of Concrete

