Related Experiment Video
Updated: Dec 30, 2025

Simple In-House Ultra-High Performance Capillary Column Manufacturing with the FlashPack Approach
Published on: December 4, 2021
Performance of small-domain monolithic silica columns in nano-liquid chromatography and comparison with commercial
Takeshi Hara1, Yoshihiro Izumi1, Kosuke Hata1
1Division of Metabolomics, Medical Institute of Bioregulation, Kyushu University, 3-1-1 Maidashi, Higashi-ku, Fukuoka 812-8582, Japan.
Abstract:
We report on a direct comparison of the separation performance in capillary nano-LC between commercial packed bed columns and the small-domain silica monoliths in applications. Octadecylsilylated monolithic silica capillary columns with a 50 and 100 µm inner diameter (i.d.) were prepared with a procedure providing domain sizes in the sub-2 µm range. The fabricated monolith columns could provide plate heights (H) of 4.0‒4.2 µm for hexylbenzene (retention factor (k) = 3.6) at an optimal linear velocity range under an isocratic condition, while showing a column permeability (Kv0 = 1.6‒1.8 × 10-14 m2) comparable to that of a column packed with 3‒3.5 µm particles. When the peak capacity (np) for a cytochrome C digest was compared for variable gradient times (tG = 15, 30, 60, and 120 min) and constant gradient steepness (b'), the present monolith columns could show a 30‒40% higher np-value than the packed capillary column with 2 µm particles (e.g. np = 180 versus np = 259 at tG = 30 min). The produced monolith columns showed a high chromatographic repeatability for both isocratic and gradient elution (e.g. relative standard deviation (n = 3, RSD (%)) = 0.5% for H, 2,6% for k, and 5.6% for Kv0 in the isocratic mode using the 100 µm i.d.-columns). The present results show that the domain sizes which can now be achieved for capillary silica monoliths are sufficiently small to result in separation efficiencies that can successfully compete with the commercial packed bed columns available for use in nano-LC applications.
Related Concept Videos
Silica Gel Column Chromatography: Overview
Polar components tend to bind strongly to the silica gel, causing them to move slowly through the column. In contrast, nonpolar compounds...
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process:
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...
Size-Exclusion Chromatography
Silica particles offer advantages such as rigidity,...
Ion-Exchange Chromatography
High-Performance Liquid Chromatography: Elution Process

