Noninvasive measurement of blood pressure in African green monkeys (Cercopithecus aethiops)
N Kraft-Schreyer1, E T Angelakos1
1Department of Physiology and Biophysics, Hahnemann University, Philadelphia.
Abstract:
Indirect measurements of arterial blood pressure were made in African green monkeys (Cercopithecus aethiops) employing a Doppler ultrasound stethoscope and standard cuff and an Infrasonde automatic blood pressure recorder. Measurements were obtained from anesthetized (10 mg/kg ketamine (HCI) and unanesthetized (1.5 mg/kg ketamine HCI) animals. Ketamine had no significant effect on blood pressure. Indirect measurements from the brachial artery were compared with direct femoral artery measurements and with each other. Systolic blood pressures measured by the Doppler (r = .948) and Infrasonde (r = .920) methods correlated closely with direct measurements but were significantly lower than systolic blood pressures measured by the direct method. Diastolic blood pressures measured by the Infrasonde method agreed closely with direct measurements (r = .947). Systolic blood pressures measured by the indirect methods correlated closely in both anesthetized (r = .973) and unanesthetized (r = .834) animals and were not significantly different. Mean blood pressures calculated from direct and Infrasonde measurements also correlated closely (r = .963), with direct measurements being 4 mmHg higher on the average. Mean blood pressures are less influenced by methodology and are more reproducible than other pressures. These noninvasive methods can be used to obtain simple and accurate measurements of blood pressure from anesthetized and unanesthetized monkeys and are of value in long-term studies in monkeys.
More Related Videos
07:52Author Spotlight: Investigating Vocal Information Representation in Small Primates and Its Alteration by Psychiatric Disorders Using Noninvasive EEG
Published on: July 26, 2024
08:54Measuring Blood Pressure in Mice using Volume Pressure Recording, a Tail-cuff Method
Published on: May 15, 2009
Related Concept Videos
Measurement of Blood Pressure
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Sites for measruring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure:
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment: