Toric intraocular lens in asymmetric astigmatism
Sergio Kwitko1, Samara Barbara Marafon2, Andressa Prestes Stolz1
1Ophthalmology Department, Oftalmocentro, Av. Nilo Peçanha, 724/401, Porto Alegre, RS, Brazil.
International Ophthalmology
|January 27, 2020
Summary
Toric intraocular lens (IOL) implantation effectively reduces refractive cylinder in patients with asymmetric astigmatism, improving visual acuity and reducing spectacle dependence. This offers a safe and beneficial option for those intolerant to contact lenses.
Area of Science:
- Ophthalmology
- Refractive Surgery
- Corneal Surgery
Background:
- Asymmetric astigmatism presents challenges for visual correction.
- Patients intolerant to contact lenses or with unsatisfactory spectacle correction require alternative solutions.
- Toric intraocular lenses (IOLs) are designed to correct astigmatism during cataract surgery.
Purpose of the Study:
- To evaluate the efficacy and safety of toric IOL implantation in patients with asymmetric astigmatism.
- To assess the reduction in refractive cylinder and improvement in visual acuity.
- To determine the suitability of toric IOLs for individuals with specific corneal conditions and contact lens intolerance.
Main Methods:
- Retrospective cohort study of 88 eyes from 69 patients with various causes of asymmetric astigmatism.
- Patients underwent cataract surgery with toric IOL implantation, with lens selection based on optical biometry.
- Surgeries were performed by a single surgeon using a standardized technique.
Main Results:
- Best-corrected spectacle visual acuity improved significantly from 0.39 preoperatively to 0.80 postoperatively.
- Average refractive cylinder decreased from 2.32 D to 0.87 D (P < .001).
- 71% of eyes achieved a residual refractive cylinder of 1.0 D or less.
Conclusions:
- Toric IOL implantation is effective in managing asymmetric astigmatism.
- The procedure leads to improved visual acuity and reduced spectacle dependence.
- Toric IOLs offer a valuable solution for contact lens-intolerant patients seeking better vision quality.
Related Concept Videos
Angle Closure Glaucoma: Treatment
1.1K
Angle-closure glaucoma, or closed-angle glaucoma, is an eye condition where the iris bulges out and blocks the iridocorneal angle, resulting in a buildup of aqueous humor and increased intraocular pressure. Immediate medical attention is necessary due to the sudden onset of symptoms. The treatment for angle-closure glaucoma includes short-term and long-term approaches. Short-term treatment involves using eye drops like pilocarpine to lower intraocular pressure by increasing aqueous humor...
1.1K
Open Angle Glaucoma: Treatment
901
In open-angle glaucoma, the iridocorneal angle remains open, but the trabecular meshwork becomes stiff, slowing down the outflow of aqueous humor. This causes a buildup of aqueous humor in the anterior chamber, leading to a sudden increase in intraocular pressure. The treatment for open-angle glaucoma focuses on reducing the elevated intraocular pressure by either decreasing the secretion of aqueous humor or increasing its outflow.
Drugs such as carbonic anhydrase inhibitors, α2- and...
Drugs such as carbonic anhydrase inhibitors, α2- and...
901
Glaucoma: Overview
1.1K
Glaucoma is an eye condition characterized by increased intraocular pressure that damages the retina and optic nerve, leading to irreversible blindness if left untreated. The human eye has various components, including the cornea, iris, pupil, lens, and optic nerve. Aqueous humor is secreted by the epithelium of the ciliary body in the posterior chamber and flows through the trabecular meshwork and canal of Schlemm, maintaining normal intraocular pressure. The trabecular meshwork and the canal...
1.1K
Focusing of Light in the Eye
5.0K
Light rays enter the eye through the cornea, a transparent dome-shaped tissue that is the eye's outermost layer. The cornea bends or refracts, light rays traveling to the pupil. The shape of the cornea determines how much of the light is bent and whether the image will be focused correctly on the retina at the back of the eye. Once the light has passed through both refraction layers, it converges into a single focal point onto a small area. This is where photoreceptors start transforming...
5.0K
Rotation of Asymmetric Top
1.4K
By definition, a spherically symmetric body has the same moment of inertia about any axis passing through its center of mass. This situation changes if there is no spherical symmetry. Since most rigid bodies are not spherically symmetric, these require special treatment.
The relationship between the angular momentum of any rigid body and its angular velocity, both of which are vectors, involves the moment of inertia. The moment of inertia is a scalar quantity only for spherically symmetric...
The relationship between the angular momentum of any rigid body and its angular velocity, both of which are vectors, involves the moment of inertia. The moment of inertia is a scalar quantity only for spherically symmetric...
1.4K