Robust control of automatic voltage regulator (AVR) with real structured parametric uncertainties based on H∞ and μ-analysis
Related Experiment Video
Updated: Dec 30, 2025

Experimental Investigation of the Hierarchical Control in DC Microgrids Using a Real-time Simulator
Published on: February 14, 2025
Mohammadreza Modabbernia1, Behnam Alizadeh1, Alireza Sahab1
1Department of Electrical Engineering, Lahijan Branch, Islamic Azad University, Lahijan, Iran.
Abstract:
Within this work, a novel controller in terms of H infinity (H∞) and structured singular value decomposition has been presented to provide the robust performance of the Automatic Voltage Regulator (AVR) system Six real structured uncertainties in actuator, exciter and generator have been assumed for the linear transfer functions of the AVR system. Each uncertain parameter varies between a minimum and a maximum value due to the load variations in a period of time and aging effects over the life time. The efficiency of the presented design lies on two main reasons. The first is the simultaneous considering of the output disturbances, sensor noises and system uncertainties in the controller design approach. The second is the non-conservative modeling of all six structured parameters in the required μ-synthesis P-Δ-K configuration. By suboptimal H∞ control design technique and μ-analysis theorem, a single input single output (SISO) controller comprising a closed loop system with μ<1 is obtained. The offered controller's supremacy is represented through comparison of its performance with some other optimized PID, PIDD fractional order PID (FOPID), fuzzy + PID and Interval Type-2 fuzzy logic controllers by heuristic optimization algorithms. The simulation outcomes indicate that the provided robust controller for the AVR system has the better performance than the other optimized and fuzzy controllers in a wide range of the uncertainties. Also, the better behavior of the intended robust controller was shown in two benchmarks: a single machine connected to a 230kV network, and a four-machine two-area test system.
More Related Videos
06:45Design and Application of a Fault Detection Method Based on Adaptive Filters and Rotational Speed Estimation for an Electro-Hydrostatic Actuator
Published on: October 28, 2022
11:53The Modular Design and Production of an Intelligent Robot Based on a Closed-Loop Control Strategy
Published on: October 14, 2017
Related Concept Videos
PI Controller: Design
Time-Domain Interpretation of PD Control
Consider the example of control of motor torque. Initially, a positive...
Multimachine Stability
In analyzing the system, the nodal equations represent the relationship between bus voltages, machine voltages, and machine currents. The nodal equation is given by:
Routh-Hurwitz Criterion I
To apply the Routh-Hurwitz criterion, a Routh table is constructed. The table's rows are labeled with powers of the complex frequency variable s, starting from the...
Propagation of Uncertainty from Systematic Error
Time and frequency -Domain Interpretation of PI Control
Acting as a low-pass filter, the PI controller slows the system's response and extends settling times. This requires...