Related Experiment Video
Updated: Dec 30, 2025

How to Administer Near-Infrared Spectroscopy in Critically ill Neonates, Infants, and Children
Published on: August 19, 2020
Oxygen saturation target ranges and alarm settings in the NICU: What have we learnt from the neonatal oxygenation
Barbara Schmidt1, Robin K Whyte2
1Department of Pediatrics, Perelman School of Medicine, University of Pennsylvania, Philadelphia, PA, USA; Department of Health Research Methods, Evidence and Impact, McMaster University, Hamilton, Ontario, Canada.
Abstract:
The Neonatal Oxygenation Prospective Meta-analysis combined the individual participant data of 4965 extremely preterm infants. They had been randomly assigned in 5 trials to arterial oxygen saturations of 85%-89% or 91%-95% using modified oximeters to mask the treatment allocation. The primary outcome of death or disability did not differ significantly between the groups. Assignment to the higher target range reduced the risks of death and severe necrotizing enterocolitis but increased the risk of treated retinopathy. Trade-offs between the benefits and risks of higher or lower saturation targets should be informed by the local patient risks and institutional rates for outcomes that may be affected by a policy change. Features of the oximeter masking algorithm introduced unanticipated artifacts into the saturation display that are not seen in routine care. NeOProM provides little guidance on where to set the oximeter alarms and how to respond to them.
More Related Videos
Related Concept Videos
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is...
Respiratory Assessment: Purpose and Indications
Objectives and Importance:
The primary goal of respiratory assessment is to evaluate patients at early risk of clinical deterioration. Since respiratory distress often precedes other signs of declining health, breathing patterns and sounds become a...
Oxygen Delivering System I: Nasal Cannula and Face Mask
Nasal Cannula
A nasal cannula is a lightweight tube split at one end into two prongs and placed in the nostrils. It is typically used to deliver low to medium levels of oxygen.
Suggested flow rate: The suggested flow rate for a nasal cannula typically ranges between 1 and 6 L/min.
Oxygen percentage setting:...
Guidelines For Measuring Vital Signs
Before taking a patient's vital signs, a nurse would consider and assess the patient's comfort level and ensure appropriate equipment is available.
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...