Related Experiment Video
Updated: Dec 30, 2025

Optimization of the Epimedii Folium Mutton-Oil Processing Technology and Testing Its Effect on Zebrafish Embryonic Development
Published on: March 17, 2023
Modelling of bioprocess non-linear fluorescence data for at-line prediction of etanercept based on artificial neural
Fabricio A Chiappini1, Carla M Teglia1, Ángela G Forno2
1Laboratorio de Desarrollo Analítico y Quimiometría (LADAQ), Cátedra de Química Analítica I, Facultad de Bioquímica y Ciencias Biológicas (FBCB), Universidad Nacional Del Litoral (UNL), Ciudad Universitaria, Santa Fe, S3000ZAA, Argentina; Consejo Nacional de Investigaciones Científicas y Técnicas (CONICET), Godoy Cruz 2290 CABA, C1425FQB, Argentina.
Abstract:
In the last years, regulatory agencies in biopharmaceutical industry have promoted the design and implementation of Process Analytical Technology (PAT), which aims to develop rapid and high-throughput strategies for real-time monitoring of bioprocesses key variables, in order to improve their quality control lines. In this context, spectroscopic techniques for data generation in combination with chemometrics represent alternative analytical methods for on-line critical process variables prediction. In this work, a novel multivariate calibration strategy for the at-line prediction of etanercept, a recombinant protein produced in a mammalian cells-based perfusion process, is presented. For data generation, samples from etanercept processes were daily obtained, from which fluorescence excitation-emission matrices were generated in the spectral ranges of 225.0 and 495.0 nm and 250.0 and 599.5 nm for excitation and emission modes, respectively. These data were correlated with etanercept concentration in supernatant (measured by an off-line HPLC-based reference univariate technique) by implementing different chemometric strategies, in order to build predictive models. Partial least squares (PLS) regression evidenced a non-linear relation between signal and concentration when observing actual vs. predicted concentrations. Hence, a non-parametric approach was implemented, based on a multilayer perceptron artificial neural network (MLP). The MLP topology was optimized by means of the response surface methodology. The prediction performance of MLP model was superior to PLS, since the first is able to cope with non-linearity in calibration models, reaching percentage mean relative error in predictions of about 7.0% (against 12.6% for PLS). This strategy represents a fast and inexpensive approach for etanercept monitoring, which conforms the principles of PAT.
More Related Videos
Related Concept Videos
Model-Independent Approaches for Pharmacokinetic Data: Noncompartmental Analysis
One important characteristic of noncompartmental analyses is that drug exposure increases proportionally with increasing doses. This...
Model Approaches for Pharmacokinetic Data: Distributed Parameter Models
The distributed parameter models are specifically designed to account for variations and differences in some drug classes. This model is particularly useful for assessing regional concentrations of anticancer or...
Analysis of Population Pharmacokinetic Data
Analysis Methods of Pharmacokinetic Data: Model and Model-Independent Approaches
The model approach uses mathematical models to describe changes in drug concentration over time. Pharmacokinetic models help characterize drug behavior in patients, predict drug concentration in the body fluids, calculate optimum dosage regimens, and evaluate the risk of toxicity. However, ensuring that the model fits the experimental data accurately...
Nonlinear Pharmacokinetics: Bioavailability and Protein-Drug Binding
To quantify the extent of bioavailability, pharmacologists often use a parameter called .
Nonlinear Pharmacokinetics: Causes of Nonlinearity
Nonlinear drug absorption can occur when the process is rate-limited by solubility, carrier-mediated transport systems, or saturation of the presystemic gut wall or hepatic metabolism. For instance, high doses of riboflavin...

