Large-scale Top-down Proteomics Using Capillary Zone Electrophoresis Tandem Mass Spectrometry
Published on: October 24, 2018
Hyphenation of capillary zone electrophoresis with mass spectrometry for proteomic analysis: Optimization and
Marie-Jia Gou1, Gwenaël Nys1, Gaël Cobraiville1
1Laboratory for the Analysis of Medicines, Center for Interdisciplinary Research on Medicines (CIRM), University of Liege, Quartier hopital, Avenue Hippocrate 15, 4000 Liege, Belgium.
Abstract:
Capillary electrophoresis tandem mass spectrometry (CE-MS/MS) is an interesting tool for proteomic analysis as the separation principle is orthogonal to liquid chromatography tandem mass spectrometry (LC-MS/MS). The combination of both techniques can bring complementary information to enlarge proteome coverage. In this study, sample preconcentration techniques were investigated in order to improve sample loading and therefore sensitivity. Dynamic pH junction (DPJ) was found to be the most interesting approach by using 200 mM ammonium acetate (NH4Ac) adjusted to pH 10.0 as sample matrix. The use of DPJ allowed the identification of more peptides and proteins compared to conventional injections. Moreover, the sheath liquid (SL) composition was optimized in order to enhance signal intensity. A nanoflow SL interface (EMASS-II) was compared to the traditional coaxial SL interface (Triple tube) in terms of number of identified and proteins as well as detection sensitivity (peak area and peak height). MS acquisition was performed using both data-dependent acquisition (DDA) and data-independent acquisition (DIA) modes. The results showed that the combined use of these two acquisition modes provided additional information in terms of identification. Moreover, the use of EMASS-II interface allowed the identification of approximately two times more peptides and proteins. Besides, there was an improvement in sensitivity using EMASS-II as peak height and peak area were improved by 4 and 6-fold, respectively, compared to the Triple tube. Altogether, by combining an efficient sample preconcentration method, a nanoflow CE-MS interface and a hybrid ion-mobility qTOF mass spectrometer, a satisfying sequence coverage was obtained by analyzing 1 µg of E. coli proteome digest.
More Related Videos
07:46Sheathless Capillary Electrophoresis–Mass Spectrometry for Metabolic Profiling of Biological Samples
Published on: October 1, 2016
05:45Capillary Electrophoresis-based Hydrogen/Deuterium Exchange for Conformational Characterization of Proteins with Top-down Mass Spectrometry
Published on: June 8, 2021
Related Concept Videos
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...
Capillary Electrophoresis: Instrumentation
Peptide Identification Using Tandem Mass Spectrometry
This technique helps gather information regarding the protein from which the peptide was obtained and to study the peptides’ amino acid sequence. Identifying peptides from a complex mixture is an important component of the growing field of...
Electrophoresis: Overview
There...
Tandem Mass Spectrometry