Related Experiment Video
Updated: Dec 29, 2025

High-Resolution Endocardial and Epicardial Optical Mapping in a Sheep Model of Stretch-Induced Atrial Fibrillation
Published on: July 29, 2011
Could you say that was an atrial flutter or not?
Serkan Özsoylu1, Başak Nur Akyıldız1, Adem Dursun1
1Divisions of Pediatric Intensive Care Unit, Erciyes University Faculty of Medicine, Kayseri, Turkey.
Abstract:
Özsoylu S, Akyıldız BN, Dursun A, Pamukçu Ö. Could you say that was an atrial flutter or not? Turk J Pediatr 2019; 61: 608-610. Muscle-tremor artefact is a potential cause of misdiagnosis of atrial arrhythmias on electrocardiography (ECG) monitoring. Such errors may lead to inappropriate and potentially dangerous therapies in some patients. We present a case of a patient with uncontrolled seizures whose bedside electrocardiogram monitor analysis appeared to demonstrate atrial flutter with 4:1 conduction through the AV node. The ECG monitor and ECG rhythm strip additionally showed a regular ventricular rate of 94 bpm with an underlying regular `saw-tooth` baseline. We applied cardioversion to convert to sinus rhythm. Amiodarone was loaded and added to the patients therapy who had atrial flutter after cardioversion. Echocardiogram was performed by a pediatric cardiologist and they noted that the atrial rate and ventricular rate were equal. After this, we began to suspect this situation might be a pseudoflutter due to his muscle contractions. We applied rocuronium to the patient to understand whether this was a pseudo-flutter or not. We saw that the ECG returned to normal sinus rhythm. Physicians especially working in intensive care units should be aware of artifact to avoid unnecessary therapeutic procedures. As Hippocrates said centuries ago `First, do no harm.`.
More Related Videos
10:39Rat Model of Right-Sided Cardiac Remodeling and Arrhythmia Using Pulmonary Artery Banding
Published on: August 30, 2024
08:10Estimating Bilateral Atrial Function by Cardiovascular Magnetic Resonance Feature Tracking in Patients with Paroxysmal Atrial Fibrillation
Published on: July 20, 2022
Related Concept Videos
ECG Interpretation of Arrhythmias II: Atrial, Junctional and Ventricular Arrhythmias
Dysrhythmias III: Characteristics of Dysrhythmias
Disturbances in Heart Rhythm
Arrhythmias are categorized by their speed, rhythm, and origin. A slow heart...
Dysrhythmias II: Classification of Tachyarrhythmias
Dysrhythmias IV: Characteristics of Bradyarrhythmias
The Cardiac Cycle
The Process
Electrical signals—sent from the sinoatrial (SA) node in the right atrial wall to the atrioventricular (AV) node between the right atrium and right ventricle—cause both atria to simultaneously contract. When the signal reaches the AV node, it pauses for approximately a tenth of a second, allowing the atria to contract and...