Related Experiment Video
Updated: Dec 29, 2025

Halogenated Agent Delivery in Porcine Model of Acute Respiratory Distress Syndrome via an Intensive Care Unit Type Device
Published on: September 24, 2020
High-Flow Nasal Cannula May Not Reduce the Re-Intubation Rate Compared With a Large-Volume Nebulization-Based
Wataru Matsuda1, Akiyoshi Hagiwara2, Tatsuki Uemura3
1Department of Emergency Medicine and Critical Care, Center Hospital of the National Center for Global Health and Medicine, Shinjuku-ku, Tokyo, Japan. wmatsuda@hosp.ncgm.go.jp.
Background:
High-flow nasal cannula (HFNC) therapy may reduce the re-intubation rate compared with conventional oxygen therapy. However, HFNC has not been sufficiently compared with conventional oxygen therapy with a heated humidifier, even though heated humidification is beneficial for facilitating airway clearance.
Methods:
This study was a single-center, open-label, randomized controlled trial. We randomized subjects with respiratory failure after extubation to either HFNC group or to a large-volume humidified nebulization-based nebulizer. The primary end point was the re-intubation rate within 7 d after extubation.
Results:
We could not recruit enough subjects for the sample size we designed, therefore, we analyzed 69 subjects (HFNC group, 30 subjects; nebulizer group, 39 subjects). The re-intubation rate within 7 d was not significantly different between the HFNC and nebulizer groups (5/30 subjects [17%] and 6/39 subjects [15%], respectively; P > .99). [Formula: see text]/set [Formula: see text] at 24 h after extubation was also not significantly different between the respective groups (264 ± 105 mm Hg in the HFNC group vs 224 ± 53 mm Hg in the nebulizer group; P = .07).
Conclusions:
Compared with a large-volume nebulization-based humidifier, HFNC may not reduce the re-intubation rate within 7 d. However, because of insufficient statistical power, further studies are needed to reach a conclusion.
More Related Videos
05:43Topical Airway Anesthesia for Awake-endoscopic Intubation Using the Spray-as-you-go Technique with High Oxygen Flow
Published on: January 13, 2017
05:44Novel Methods for Intranasal Administration Under Inhalation Anesthesia to Evaluate Nose-to-Brain Drug Delivery
Published on: November 14, 2018
Related Concept Videos
Administering Oxygen by Nasal Cannula
Nasal Cannulas
A nasal cannula is a lightweight tube split into two prongs placed in the nostrils,...
Oxygen Delivering System I: Nasal Cannula and Face Mask
Nasal Cannula
A nasal cannula is a lightweight tube split at one end into two prongs and placed in the nostrils. It is typically used to deliver low to medium levels of oxygen.
Suggested flow rate: The suggested flow rate for a nasal cannula typically ranges between 1 and 6 L/min.
Oxygen percentage setting:...
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation...
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
Suctioning the Nasopharyngeal Airway
Equipment Required