Improving peak capacities over 100 in less than 60 seconds: operating above normal peak capacity limits with signal
Garrett Hellinghausen1, M Farooq Wahab1, Daniel W Armstrong2
1Department of Chemistry and Biochemistry, The University of Texas at Arlington, Arlington, TX, 76019, USA.
Abstract:
A primary focus in liquid chromatography analysis of complex samples is high peak capacity separations. Using advanced instrumentation and optimal small, high-efficiency columns, complex multicomponent mixtures can now be analyzed in relatively short times. Despite these advances, chromatographic peak overlap is still observed. Recently, attention has shifted from improvements in chromatographic efficiency and selectivity to enhancing data processing after collection. Curve fitting methods can be used to trace underlying peaks, but do not directly enhance chromatographic resolution. Methods based on the properties of derivatives and power transform were recently shown to enhance chromatographic peak resolution while maintaining critical peak information (peak areas and retention times). These protocols have been extensively investigated for their fundamental properties, advantages, and limitations, but they have not been evaluated with complex chromatograms. Herein, we evaluate the use of deconvolution via Fourier transform (FT), even-derivative peak sharpening, and power law with the fast separation (< 60 s) of a 101-component mixture using ultra-high-pressure liquid chromatography. High noise and peak overlap are present in this gradient separation, which is representative of fast chromatography. Chromatographic resolution enhancement is demonstrated and described. Further, accurate quantitation is maintained and shown with representative examples. Enhancements in peak capacity and peak-to-peak resolutions are discussed. Finally, the statistical theory of overlap is used for 101 peaks and predictions are made for the number of singlet, doublet, and multiplets analyte peaks. The effect of increasing peak capacity by FT even derivative sharpening and power laws leads to a decrease in the number of peak overlaps and an increase in total peak number. Graphical abstract.
Related Concept Videos
Upsampling
Basic Operations on Signals
Time Reversal mirrors a continuous-time signal about the vertical axis at t=0. This is achieved by substituting t with −t. For example, if a signal x(t) is considered, the time-reversed signal is x(−t). This operation can be graphically represented, showing the mirrored signal.
Design Example: Vintage Mixing Console
The specifications for the pre-amplifier were clear. It needed to amplify the audio signal by a factor of 10, have an input impedance above 10...
Maximum Power Transfer
By substituting the entire circuit with...
Reconstruction of Signal using Interpolation
Design Example: Capacitance Multiplier Circuit
The circuit illustrated in Figure 1 below incorporates two op-amps, with the first operating as a voltage follower and the second acting as an inverting amplifier.


