Related Experiment Video
Updated: Dec 29, 2025

Intraoperative Gastroscopy for Tumor Localization in Laparoscopic Surgery for Gastric Adenocarcinoma
Published on: August 9, 2016
Assessment of 3-Dimensional vs 2-Dimensional Imaging and Technical Performance Using a Multiport Intraoperative Data
Mauricio E Gabrielli1,2,3, Tomas J Saun4, James J Jung3
1International Centre for Surgical Safety, St Michael's Hospital, Toronto, Ontario, Canada.
Importance:
Errors and adverse events occur frequently in health care. Three-dimensional (3-D) laparoscopic systems claim to provide more realistic depth perception and better spatial orientation compared with their 2-D counterparts.
Objective:
To compare the association of 3-D vs 2-D systems with technical performance during laparoscopic Roux-en-Y gastric bypass (LRYGB) procedures using a multiport intraoperative data capture system.
Design, Setting, And Participants:
This cohort study was performed between May and December 2018, with a total of 50 LRYGB procedures performed in an academic tertiary care center; recordings of the operations were evaluated with a 30-day follow-up. All procedures were performed by the same surgical team.
Exposure:
Surgical teams used 2-D or 3-D laparoscopic systems.
Main Outcomes And Measures:
Technical performance was evaluated using the Objective Structured Assessment of Technical Skill and surgical errors and events using the Generic Error Rating Tool.
Results:
Of the 50 patients who underwent LRYGB procedures, 42 (86%) were women, with a median (interquartile range) age of 42 (35-47) years and a median (interquartile range) body mass index of 46 (42-48), with no significant demographic differences between the groups whose operations were performed using the 2-D and 3-D systems. The mean (SD) number of errors per case was significantly lower in procedures using the 3-D laparoscopic system than in those using the 2-D system (17 [6] vs 33 [2]; P < .001). The mean (SD) number of error-related events was significantly lower in procedures using the 3-D system than in those using the 2-D system (6 [2] vs 11 [4]; P < .001). Mean (SD) Objective Structured Assessment of Technical Skill scores were significantly higher when the 3-D system was used than when the 2-D system was used (28 [4] vs 22 [3]; P < .001).
Conclusions And Relevance:
In this limited sample of LRYGB procedures, the use of a 3-D laparoscopic system was associated with a statistically significant reduction in errors and events as well as higher Objective Structured Assessment of Technical Skill scores compared with 2-D systems.