A theoretical framework for comparing noise characteristics of spectral, differential phase-contrast and spectral
Korbinian Mechlem1, Thorsten Sellerer, Manuel Viermetz
1Chair of Biomedical Physics, Department of Physics and Munich School of BioEngineering, Technical University of Munich, 85748 Garching, Germany. Author to whom any correspondence should be addressed.
Abstract:
Spectral and grating-based differential phase-contrast (DPC) x-ray imaging are two emerging technologies that offer additional information compared with conventional attenuation-based x-ray imaging. In the case of spectral imaging, energy-resolved measurements allow the generation of material-specific images by exploiting differences in the energy-dependent attenuation. DPC imaging uses the phase shift that an x-ray wave exhibits when traversing an object as contrast generation mechanism. Recently, we have investigated the combination of these two imaging techniques (spectral DPC imaging) and demonstrated potential advantages compared with spectral imaging. In this work, we present a noise analysis framework that allows the prediction of (co-) variances and noise power spectra for all three imaging methods. Moreover, the optimum acquisition parameters for a particular imaging task can be determined. We use this framework for a performance comparison of all three imaging methods. The comparison is focused on (projected) electron density images since they can be calculated with all three imaging methods. Our study shows that spectral DPC imaging enables the calculation of electron density images with strongly reduced noise levels compared with the other two imaging methods for a large range of clinically relevant pixel sizes. In contrast to conventional DPC imaging, there are no long-range noise correlations for spectral DPC imaging. This means that excessive low frequency noise can be avoided. We confirm the analytical predictions by numerical simulations.
Related Concept Videos
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
X-ray Imaging
X-ray Crystallography
Diffraction
Diffraction is the change in the direction of travel experienced by an electromagnetic wave when it encounters a physical barrier whose dimensions are comparable to those of the wavelength of the light. X-rays are electromagnetic radiation with wavelengths about as long as the distance between neighboring...