Detection and Remediation of Misidentification Errors in Radiology Examination Ordering
Scott E Sheehan1, Nasia Safdar2, Hardeep Singh3
1Department of Radiology, William S. Middleton Veterans Hospital, Madison, Wisconsin, United States.
Background:
Despite progress in patient safety, misidentification errors in radiology such as ordering imaging on the wrong anatomic side persist. If undetected, these errors can cause patient harm for multiple reasons, in addition to producing erroneous electronic health records (EHR) data.
Objectives:
We describe the pilot testing of a quality improvement methodology using electronic trigger tools and preimaging checklists to detect "wrong-side" misidentification errors in radiology examination ordering, and to measure staff adherence to departmental policy in error remediation.
Methods:
We retrospectively applied and compared two methods for the detection of "wrong-side" misidentification errors among a cohort of all imaging studies ordered during a 1-year period (June 1, 2015-May 31, 2016) at our tertiary care hospital. Our methods included: (1) manual review of internal quality improvement spreadsheet records arising from the prospective performance of preimaging safety checklists, and (2) automated error detection via the development and validation of an electronic trigger tool which identified discrepant side indications within EHR imaging orders.
Results:
Our combined methods detected misidentification errors in 6.5/1,000 of study cohort imaging orders. Our trigger tool retrospectively identified substantially more misidentification errors than were detected prospectively during preimaging checklist performance, with a high positive predictive value (PPV: 88.4%, 95% confidence interval: 85.4-91.4). However, two third of errors detected during checklist performance were not detected by the trigger tool, and checklist-detected errors were more often appropriately resolved (p < 0.00001, 95% confidence interval: 2.0-6.9; odds ratio: 3.6).
Conclusion:
Our trigger tool enabled the detection of substantially more imaging ordering misidentification errors than preimaging safety checklists alone, with a high PPV. Many errors were only detected by the preimaging checklist; however, suggesting that additional trigger tools may need to be developed and used in conjunction with checklist-based methods to ensure patient safety.
More Related Videos
Related Concept Videos
Radiological Investigation I: X-ray and CT
Documentation of Nursing Diagnosis
In some settings, data-driven computerized decision support systems are in place, allowing for more accurate nursing diagnoses. The database within one of these systems includes diagnostic labels defining characteristics, activities, and indicators for nursing. A nurse enters...
Errors occurring during blood pressure monitoring
Several factors...
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Guidelines and Strategies for Safe Computer Charting
Maintain Confidentiality and Security:
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...