Related Experiment Video
Updated: Dec 29, 2025

A Fibrin-Enriched and tPA-Sensitive Photothrombotic Stroke Model
Published on: June 4, 2021
Dense and dangerous: The tissue plasminogen activator-resistant fibrinolysis shutdown phenotype is due to abnormal
Nathan Dow1, Julia R Coleman, Hunter Moore
1From the Department of Surgery (N.D., Z.T.O., A.M.S., K.F.), University of Vermont, Burlington, Vermont; Ernest E Moore Shock Trauma Center at Denver Health (J.R.C., H.M., E.E.M.), University of Colorado Denver, Denver, Colorado; Department of Pharmacology (G.H., M.T.N.), University of Vermont, Burlington; and Department of Biochemistry (S.B.), University of Vermont, Colchester, Vermont.
Background:
Both hyperfibrinolysis and fibrinolysis shutdown can occur after severe trauma. The subgroup of trauma patients with fibrinolysis shutdown resistant to tissue plasminogen activator (t-PA)-mediated fibrinolysis have increased mortality. Fibrin polymerization and structure may influence fibrinolysis subgroups in trauma, but fibrin architecture has not been characterized in acutely injured subjects. We hypothesized that fibrin polymerization measured in situ will correlate with fibrinolysis subgroups.
Methods:
Blood samples were collected from trauma patients and noninjured controls. We selected samples across a range of fibrinolysis phenotypes (shutdown, physiologic, hyperfibrinolysis) and t-PA sensitivities (sensitive, physiologic, resistant) determined by thrombelastography. Plasma clots were created in situ with fluorescent fibrinogen and imaged using confocal microscopy for analysis of clot architecture in three dimensions. For each clot, we quantified the fiber resolvability, a metric of fiber distinctness or clarity, by mapping the variance of fluorescence intensity relative to background fluorescence. We also determined clot porosity by measuring the size and distribution of the gaps between fibrin fibers in three-dimensional space. We compared these measures across fibrinolysis subgroups.
Results:
Fiber resolvability was significantly lower in all trauma subgroups compared with controls (n = 35 and 5, respectively; p < 0.05). We observed markedly different patterns of fibrin architecture among trauma patients stratified by fibrinolysis subgroup. Subjects with t-PA-resistant fibrinolysis shutdown exhibited abnormal, densely packed fibrin clots nearly devoid of pores. Individuals with t-PA-hypersensitive fibrinolysis shutdown had highly irregular clots with pores as large as 2500 μm to 20,000 μm, versus 78 μm to 1250 μm in noninjured controls.
Conclusion:
Fiber resolvability was significantly lower in trauma patients than controls, and subgroups of fibrinolysis differ in the porosity of the fibrin clot structure. The dense fibrin network in the t-PA-resistant group may prevent access to plasmin, suggesting a mechanism for thrombotic morbidity after injury.
More Related Videos
Related Concept Videos
Clot Retraction and Fibrinolysis
Anticoagulant Drugs: Low-Molecular-Weight Heparins
Amyloid Fibrils
Amyloid deposits were observed as early as 1639 in the liver and the spleen. In 1854, Rudolph Virchow performed iodine staining,...
Extrinsic and Intrinsic Pathways of Hemostasis
The Extrinsic Pathway
The extrinsic pathway of coagulation is typically initiated by tissue damage that exposes blood to tissue factor (TF), a protein released by the damaged tissue cells outside the blood vessels—this interaction with TF triggers biochemical reactions involving specific clotting factors. The key player here is Factor VII, which...
Disassembly of Intermediate Filaments
Keratin proteins, found at the cell periphery near cell junctions, undergo a cycle of assembly and disassembly. In Type...
Actin Filament Depolymerization
In F-actin, the ADF/cofilin proteins...

