Related Experiment Video
Updated: Dec 29, 2025

An Inertial Measurement Unit Based Method to Estimate Hip and Knee Joint Kinematics in Team Sport Athletes on the Field
Published on: May 26, 2020
A novel acquisition platform for long-term breathing frequency monitoring based on inertial measurement units
Ambra Cesareo1, Emilia Biffi2, David Cuesta-Frau3
1Dipartimento di Elettronica, Informazione e Bioingegneria, Politecnico di Milano, Piazza Leonardo da Vinci, 32, 20133, Milan, Italy.
Abstract:
Continuous monitoring of breathing frequency (fB) could foster early prediction of adverse clinical effects and exacerbation of medical conditions. Current solutions are invasive or obtrusive and thus not suitable for prolonged monitoring outside the clinical setting. Previous studies demonstrated the feasibility of deriving fB by measuring inclination changes due to breathing using accelerometers or inertial measurement units (IMU). Nevertheless, few studies faced the problem of motion artifacts that limit the use of IMU-based systems for continuous monitoring. Moreover, few attempts have been made to move towards real portability and wearability of such devices. This paper proposes a wearable IMU-based device that communicates via Bluetooth with a smartphone, uploading data on a web server to allow remote monitoring. Two IMU units are placed on thorax and abdomen to record breathing-related movements, while a third IMU unit records body/trunk motion and is used as reference. The performance of the proposed system was evaluated in terms of long-acquisition-platform reliability showing good performances in terms of duration and data loss amount. The device was preliminarily tested in terms of accuracy in breathing temporal parameter measurement, in static condition, during postural changes, and during slight indoor activities showing favorable comparison against the reference methods (mean error breathing frequency < 5%). Graphical abstract Proof of concept of a wearable, wireless, modular respiratory Holter based on inertial measurement units (IMUS) for the continuous breathing pattern monitoring through the detection of chest wall breathing-related movements.
Related Concept Videos
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Neural Control of Respiration
Respiratory Centers in the Brainstem
Two primary areas comprise the respiratory center: the medullary respiratory center in the medulla oblongata and the pontine respiratory group in the pons. The...
Assessment of Respiration
Subjective Assessment: Nurses interview the patient to gather information directly during the subjective assessment. It includes questions about the individual's medical history, medications, and symptoms, focusing on past respiratory conditions like...
Assessment of Ventilation II: Respiratory Depth and Rhythm
Respiratory depth measures the volume of air inhaled or exhaled during a breath. It can vary from shallow to deep and typically remains consistent when a person is at rest or asleep. Occasionally, individuals will automatically inhale deeply, known as sighing, which inflates the lungs with more air than normal breathing.
To assess respiratory depth, observe the degree of chest excursion or movement:
Physiological Control of Respiration
Breathing, a seemingly passive process, is regulated by the respiratory center in the brainstem. This center coordinates the involuntary control of respirations, which means it occurs without conscious effort, ensuring a smooth and uninterrupted pattern.
Regulation of Ventilation
The body maintains ventilation by monitoring levels of carbon dioxide (CO2), oxygen (O2), and hydrogen ion concentration (pH) in the arterial blood. Among these factors, the level of CO2 plays a crucial...
Assessment of Ventilation I: Respiratory Rate
A Ventilation assessment is critical for monitoring a patient's health status. Respiration, one of the most accessible vital signs, provides insights into the function of numerous body systems and can indicate serious health issues, such as brainstem injuries from head trauma.
Critical Guidelines for Assessing Ventilation:

