Related Experiment Video
Updated: Dec 29, 2025

08:31
Three-dimensional Optical-resolution Photoacoustic Microscopy
Published on: May 3, 2011
18.7K
High acoustic numerical aperture photoacoustic microscopy with improved sensitivity
Optics Letters
|February 1, 2020
Summary
Researchers developed a high acoustic numerical aperture OR-PAM system, significantly improving sensitivity and imaging capabilities. This advancement allows for clearer visualization of biological structures with lower energy and wider views.
Area of Science:
- Biomedical Optics
- Acoustic Imaging
- Photoacoustic Microscopy
Background:
- Optical resolution photoacoustic microscopy (OR-PAM) sensitivity is limited by ultrasonic detection numerical aperture.
- Existing OR-PAM systems struggle to achieve optimal performance due to these limitations.
Purpose of the Study:
- To develop a novel OR-PAM system with a high acoustic numerical aperture (HNA-OR-PAM) to overcome sensitivity limitations.
- To enhance imaging performance, including sensitivity, penetration depth, and view angle.
Main Methods:
- Engineered an acoustic lens to achieve the highest possible acoustic numerical aperture (approximately 0.74) for a spherical concave lens.
- Developed a high acoustic numerical aperture OR-PAM (HNA-OR-PAM) system.
Main Results:
- Achieved a sensitivity improvement of approximately 160% compared to state-of-the-art OR-PAM.
- Enabled in vivo imaging of oxygen saturation with only 10-nJ pulse energy without averaging.
- Increased the photoacoustic view angle to 51.8 degrees, improving visibility of tilted features.
- Demonstrated enhanced imaging of weaker absorbers and deeper penetration.
Conclusions:
- The HNA-OR-PAM system significantly enhances sensitivity and imaging capabilities.
- The improved system allows for high-quality in vivo imaging with reduced energy requirements and an augmented view angle.
- This technology holds promise for advanced biomedical imaging applications.
Related Concept Videos
Imaging Biological Samples with Optical Microscopy
8.6K
Optical microscopy uses optic principles to provide detailed images of samples. Antonie van Leeuwenhoek designed the first compound optical microscope in the 17th century to visualize blood cells, bacteria, and yeast cells. In 1830, Joseph Jackson Lister created an essentially modern light microscope. The 20th century saw the development of microscopes with enhanced magnification and resolution.
In optical microscopy, the specimen to be viewed is placed on a glass slide and clipped on the stage...
In optical microscopy, the specimen to be viewed is placed on a glass slide and clipped on the stage...
8.6K
Super-resolution Fluorescence Microscopy
12.1K
Super-resolution fluorescence microscopy (SRFM) provides a better resolution than conventional fluorescence microscopy by reducing the point spread function (PSF). PSF is the light intensity distribution from a point that causes it to appear blurred. Due to PSF, each fluorescing point appears bigger than its actual size, and it is the PSF interference of nearby fluorophores that causes the blurred image. Various approaches to achieving higher resolution through SRFM have recently been...
12.1K
Inductively Coupled Plasma Atomic Emission Spectroscopy: Instrumentation
563
Inductively coupled plasma (ICP) is the common plasma source used in atomic emission spectroscopy (AES), a technique that detects and analyzes various elements in a sample. This method is often called inductively coupled plasma atomic emission spectroscopy (ICP-AES).
There are three main types of inductively coupled plasma atomic emission spectroscopy (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used....
There are three main types of inductively coupled plasma atomic emission spectroscopy (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used....
563

