Absorption of Radiation01:05

Absorption of Radiation

1.2K
The rate of heat transfer by emitted radiation is described by the Stefan-Boltzmann law of radiation:
1.2K

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same authorSame journal

Validation of AI-enabled surrogate models in quantitative systems pharmacology: a practical, context-of-use-driven review.

Drug discovery today·2026
Same author

EHMN 2026: A Thermodynamically Refined, SBML-Standardised Human Metabolic Network for Genome-Scale Analysis and QSP Integration.

Metabolites·2026
Same author

Lack of striatal-enriched protein tyrosine phosphatase affected the serotonin system, behavior, and brain morphology in mice.

Frontiers in psychiatry·2026
Same author

Induction of Stress Granules and Developmental Instability of Offspring Phenotype Due to Hypothermia During First Mouse Embryo Cleavage.

International journal of molecular sciences·2025
Same author

Revolutionizing drug discovery: Integrating artificial intelligence with quantitative systems pharmacology.

Drug discovery today·2025
Same author

Metagenome and metabolome study on inhaled corticosteroids in asthma patients with side effects.

Journal of integrative bioinformatics·2025

Related Experiment Video

Updated: Dec 29, 2025

An Intra-Tissue Radiometry Microprobe for Measuring Radiance In Situ in Living Tissue
09:10

An Intra-Tissue Radiometry Microprobe for Measuring Radiance In Situ in Living Tissue

Published on: June 2, 2023

973

Passive microwave radiometry in biomedical studies.

Igor Goryanin1, Sergey Karbainov2, Oleg Shevelev3

  • 1University of Edinburgh, UK; Okinawa Institute Science and Technology, Okinawa, Japan; Tianjin Institute of Industrial Biotechnology, Tianjin, China.

Drug Discovery Today
|February 1, 2020
PubMed
Summary
This summary is machine-generated.

Passive microwave radiometry (MWR) offers a noninvasive method to detect deep body temperature variations by measuring natural microwave emissions. This technique shows promise for early drug discovery and clinical applications.

More Related Videos

Using Microwave and Macroscopic Samples of Dielectric Solids to Study the Photonic Properties of Disordered Photonic Bandgap Materials
10:35

Using Microwave and Macroscopic Samples of Dielectric Solids to Study the Photonic Properties of Disordered Photonic Bandgap Materials

Published on: September 26, 2014

12.6K
Diffuse Optical Spectroscopy for the Quantitative Assessment of Acute Ionizing Radiation Induced Skin Toxicity Using a Mouse Model
06:21

Diffuse Optical Spectroscopy for the Quantitative Assessment of Acute Ionizing Radiation Induced Skin Toxicity Using a Mouse Model

Published on: May 27, 2016

8.5K

Related Experiment Videos

Last Updated: Dec 29, 2025

An Intra-Tissue Radiometry Microprobe for Measuring Radiance In Situ in Living Tissue
09:10

An Intra-Tissue Radiometry Microprobe for Measuring Radiance In Situ in Living Tissue

Published on: June 2, 2023

973
Using Microwave and Macroscopic Samples of Dielectric Solids to Study the Photonic Properties of Disordered Photonic Bandgap Materials
10:35

Using Microwave and Macroscopic Samples of Dielectric Solids to Study the Photonic Properties of Disordered Photonic Bandgap Materials

Published on: September 26, 2014

12.6K
Diffuse Optical Spectroscopy for the Quantitative Assessment of Acute Ionizing Radiation Induced Skin Toxicity Using a Mouse Model
06:21

Diffuse Optical Spectroscopy for the Quantitative Assessment of Acute Ionizing Radiation Induced Skin Toxicity Using a Mouse Model

Published on: May 27, 2016

8.5K

Area of Science:

  • Biophysics
  • Medical Imaging
  • Biotechnology

Background:

  • Passive microwave radiometry (MWR) measures natural microwave emissions (1-10GHz) from biological tissues.
  • Emission intensity correlates with biochemical and biophysical processes, though the exact mechanisms require further research.
  • Unlike infrared thermography (IRT) which measures skin surface temperature, MWR can detect thermal abnormalities deeper within the body.

Purpose of the Study:

  • To highlight the capabilities of passive microwave radiometry (MWR) for noninvasive temperature measurement.
  • To discuss the potential applications of MWR in various stages of biomedical research and clinical practice.

Main Methods:

  • Utilizes passive microwave radiometry (MWR) to detect natural microwave emissions from the human body.
  • Compares MWR's depth penetration (centimeters) with IRT's surface-level detection (microns).

Main Results:

  • MWR provides noninvasive, inexpensive deep-body temperature detection.
  • The technology does not require labels or ionizing radiation.
  • MWR can identify thermal abnormalities at depths inaccessible to IRT.

Conclusions:

  • Passive microwave radiometry (MWR) is a valuable noninvasive tool for assessing deep-body thermal status.
  • MWR has significant potential applications in early drug discovery, preclinical, and clinical studies.
  • Further research into the underlying biophysical processes is warranted to fully leverage MWR technology.