Related Experiment Video
Updated: Dec 29, 2025

Cardiac Response to β-Adrenergic Stimulation Determined by Pressure-Volume Loop Analysis
Published on: May 19, 2021
Complex high-risk and indicated percutaneous coronary intervention for stable angina: Does operator volume influence
Tim Kinnaird1, Sean Gallagher1, James C Spratt2
1Department of Cardiology, University Hospital of Wales, Cardiff, UK.
Background:
Complex high-risk and indicated revascularization using percutaneous coronary intervention (CHIP-PCI) is an emerging concept that is poorly studied.
Objective:
To define temporal changes in CHIP-PCI volumes, and the relationship between operator CHIP-PCI volume and patient outcomes.
Methods And Results:
Data were analyzed on all CHIP-PCI procedures undertaken for stable angina in England and Wales between 2007 and 2014. Operator volume data was available for 2012-14. CHIP-PCI was defined by patient characteristics (age ≥80years, left ventricular (LV) ejection fraction <30%, previous CABG, or chronic renal failure) and/or by procedural characteristics (left main PCI, chronic total occlusion PCI, LV support, use of rotational atherectomy or laser atherectomy). CHIP-PCI as a percentage of total PCI increased from 28.1% in 2007 to 36.2% in 2014 (P < .001). Between 2012 and 2014, a total of 30,268 CHIP-PCI cases were performed. Total operator volume varied from 1 to 580 cases with median total operator volume of 29 cases. Higher operator volumes were associated with a greater degree of patient comorbidity and increasing procedural complexity. After adjustment for baseline difference, in-hospital major bleeding (P < .001 for trend), access site complications (P < .001) and coronary perforation (P = .002) were associated with increasing operator CHIP-PCI volumes. However, the frequency of in-hospital death (P = .394) and 12-month mortality (P = .638) were similar across the volume quartiles. Higher volumes quartiles were associated with a greater likelihood of same day discharge (P < .001).
Conclusions:
CHIP-PCI cases are an increasingly large population in contemporary PCI practice. Higher operator volumes were not associated with improved 12-month survival.
Condensed Abstract:
Data were analyzed on all complex high-risk and indicated revascularization using percutaneous coronary intervention (CHIP-PCI) procedures in England and Wales between 2007 and 2014. CHIP-PCI as a percentage of total PCI increased from 28.1% in 2007 to 36.2% in 2014 (P < .001). Median total operator volume was 29 cases with higher volumes associated with more patient comorbidity and increasing procedural complexity. In-hospital major bleeding (P < .001 for trend), access site complications (P < .001) and coronary perforation (P = .002) all associated with increasing operator CHIP-PCI volumes. However, trends for in-hospital death (P = .394), and 12-month mortality (P = .638) were similar across the volume quartiles.
More Related Videos
04:48Noninvasive Determination of Vortex Formation Time Using Transesophageal Echocardiography During Cardiac Surgery
Published on: November 28, 2018
07:25Predicting Amputation using Local Circulating Mononuclear Progenitor Cells in Angioplasty-treated Patients with Critical Limb Ischemia
Published on: September 22, 2020
Related Concept Videos
Regulation of Stroke Volume
Preload refers to the degree of stretch on the heart before it contracts. It's analogous to the stretching of a rubber band; the more it's stretched, the more forcefully it snaps back. This concept is encapsulated in the Frank-Starling law of the...
Angina V: Nursing Management
Cardiac Output II: Effect of Stroke Volume on Cardiac Output
Preload
Preload refers to the initial elongation of the cardiac myocytes before contraction and is related to the volume of blood filling the heart at the end of diastole, or end-diastolic volume. The...
Angina IV: Management
Cardiomyopathy VII: Pre and Post Operative Nursing Management
Pathophysiology of Cardiac Performance