Related Experiment Video
Updated: Dec 29, 2025

Proton Therapy Delivery and Its Clinical Application in Select Solid Tumor Malignancies
Published on: February 6, 2019
Implementation of an optimization method for parotid gland sparing during inverse planning for head and neck cancer
N Delaby1, S Martin2, A Barateau3
1Centre Eugène Marquis, Unité de Physique Médicale, rue de La Bataille Flandres Dunkerque, CS 44229, 35042 Rennes Cedex, France.
Purpose:
To guide parotid gland (PG) sparing at the dose planning step, a specific model based on overlap between PTV and organ at risk (Moore et al.) was developed and evaluated for VMAT in head-and-neck (H&N) cancer radiotherapy.
Materials And Methods:
One hundred and sixty patients treated for locally advanced H&N cancer were included. A model optimization was first performed (20 patients) before a model evaluation (110 patients). Thirty cases were planned with and without the model to quantify the PG dose sparing. The inter-operator variability was evaluated on one case, planned by 12 operators with and without the model. The endpoints were PG mean dose (Dmean), PTV homogeneity and number of monitor units (MU).
Results:
The PG Dmean predicted by the model was reached in 89% of cases. Using the model significantly reduced the PG Dmean: -6.1±4.3Gy. Plans with the model showed lower PTV dose homogeneity and more MUs (+10.5% on average). For the inter-operator variability, PG dose volume histograms without the optimized model were significantly different compared to those with the model; the Dmean standard deviation for the ipsilateral PG decreased from 2.2Gy to 1.2Gy. For the contralateral PG, this value decreased from 2.9Gy to 0.8Gy.
Conclusion:
During the H&N inverse planning, the optimized model guides to the lowest PG achievable mean dose, allowing a significant PG mean dose reduction of -6.1Gy. Integrating this method at the treatment-planning step significantly reduced the inter-patient and inter-operator variabilities.