Related Experiment Video
Updated: Dec 29, 2025

A Two-Step Method for Percutaneous Transhepatic Choledochoscopic Lithotomy
Published on: September 13, 2022
Stone Burden Measurement by 3D Reconstruction on Noncontrast Computed Tomography Is Not a More Accurate Predictor of
Thomas Tailly1,2, Brandon R Nadeau3, Philippe D Violette2,4,5
1Division of Urology, University Hospital Ghent, Ghent, Belgium.
Abstract:
Stone burden has been reported as an independent predictor of stone-free rate after percutaneous nephrolithotomy (PCNL); however no consensus exists on a standardized method for measuring stone burden. Recently, stone volume has been advocated as the most accurate means of measuring stone burden. We aimed to compare different measuring methods of stone burden and to identify the predictive value of each for outcomes after PCNL. We performed a retrospective review of a prospective database of patients who underwent PCNL between 2006 and 2013. A preoperative CT and postoperative imaging at discharge were necessary for eligibility. Stone burden was assessed through four different ways on CT images: (1) cumulative stone diameter; (2) estimated SA (surface area) calculated as longest × orthogonal diameter × π/4; (3) manual outline of stone and computer SA calculation; and (4) automated 3D volume calculation using specific software. Primary outcome was stone-free status (SFS) at discharge. Secondary outcomes included operative time and the need for an ancillary procedure. Regression analysis and receiver operating characteristic curve analysis were used to evaluate the predictive value of each method. Of 313 included patients, 69.6% were stone free at discharge. All measures of stone burden were independent predictors of SFS [OR and 95% CI of 1.027 (1.014, 1.040), 1.481 (1.180, 1.858), 1.736 (1.266, 2.380), and 1.311 (1.127, 1.526), respectively] and demonstrated similar predictive accuracy (area under the curve = 0.630, 0.630, 0.627, and 0.638, respectively). Stone burden by any measure was an independent predictor of operative time and secondary procedure. We demonstrated that measuring stone burden by manual outline or automated 3D volume on reformatted CT images had no added value compared with orthogonal measurement for predicting outcomes after PCNL.
Related Concept Videos
Urinary Tract Calculi III: Medical Management
Urinary Tract Calculi VI: Surgical Management
Urinary Tract Calculi IV: Nutrition Therapy and Prevention
Imaging Studies III: Computed Tomography
Urinary Tract Calculi V: Nursing Management
Imaging Studies I: Kidney, Ureter, and Bladder Studies

