Related Experiment Video
Updated: Dec 29, 2025

Semi-Automated Planimetric Quantification of Dental Plaque Using an Intraoral Fluorescence Camera
Published on: January 27, 2023
Comparison of dental plaque reduction after use of electric toothbrushes with and without QLF-D-applied plaque
Sumio Akifusa1, Ayaka Isobe2, Kanako Kibata2
1School of Oral Health Sciences, Faculty of Dentistry, Kyushu Dental University, 2-6-1, Manazuru, Kokurakita-ku, Kitakyushu, Fukuoka, 803-8580, Japan. r11akifusa@fa.kyu-dent.ac.jp.
Background:
To evaluate the efficacy of a newly developed electric toothbrush in reducing dental plaque via a quantitative light-induced fluorescence-digital (QLF-D)-applied visualisation system in the brush head.
Methods:
Participants included 20 adults aged 19 to 28 years. Participants were randomly assigned either (i) an electric toothbrush with a monitor to visualise red-fluorescent dental plaque via a camera built into the brush head (monitor usage group, n = 10) or (ii) an electric toothbrush without a monitor (monitor-non-use group, n = 10). The amount of dental plaque was assessed by personal hygiene performance (PHP) at baseline and 1 week later.
Results:
In the monitor-usage group, PHP score was significantly lower at the 1-week follow-up than at baseline (6 vs 16; range, 0-12 vs 13-21; P = 0.029). This change was not observed in the monitor-non-use group (14 vs 13; range, 6-21 vs 2-26; P = 0.778). After 1 week, the change in PHP scores in the monitor usage group was significantly greater than that in the monitor non-use group (- 10 vs 0; range, - 21 to 9 vs - 8 to 16; P = 0.021).
Conclusions:
Our results clearly demonstrate that brushing teeth while looking at a monitor that depicts red-autofluorescent dental plaque via application of QLF-D improved the efficacy of dental-plaque removal relative to brushing teeth without a monitor.
Trial Registration:
Trial registration number: UMIN000033699. Name of registry: Study on effect of new devise for oral care on dental plaque clearance. Date of registration: 8th September 2018. Status of registration: Completed.