Conductance of Buckled N = 5 Armchair Graphene Nanoribbons

Jie Zhang1, Eric P Fahrenthold1

  • 1Department of Mechanical Engineering , University of Texas , Austin , Texas 78712 , United States.

Related Concept Videos

Unsymmetric Bending01:18

Unsymmetric Bending

Unsymmetrical bending occurs when the bending moment applied to a structural member does not align with its principal axis. This misalignment leads to complex stress distributions and deflection patterns that differ from those in symmetrical bending, and are essential for designing structures to withstand different loading conditions. In unsymmetrical bending, the neutral axis—where stress is zero—does not necessarily align with the geometric axes of the cross-section. The...
726
Chair Conformation of Cyclohexane02:02

Chair Conformation of Cyclohexane

The chair conformation is the most stable form of cyclohexane due to the absence of angle and torsional strain. The absence of angle strain is a result of cyclohexane’s bond angle being very close to the ideal tetrahedral bond angle of 109.5° in its chair conformer. Similarly, the torsional strain is also absent owing to the perfectly staggered arrangement of bonds.
The hydrogen atoms linked to carbons are arranged in two different axial and equatorial orientations to achieve this...
17.7K
Unsymmetric Bending - Angle of Neutral Axis01:15

Unsymmetric Bending - Angle of Neutral Axis

Unsymmetrical bending occurs when a structural member is subjected to bending moments in a plane that does not align with the member's principal axes. This scenario typically arises in beams and other structural components when loads are applied at non-ideal angles, introducing complexities in stress analysis.
When a bending moment is applied at an angle θ concerning the vertical axis of a symmetrical member, it can be resolved into components along the member's principal...
762
¹H NMR of Conformationally Flexible Molecules: Temporal Resolution00:52

¹H NMR of Conformationally Flexible Molecules: Temporal Resolution

At room temperature, the chair conformer of cyclohexane undergoes rapid ring flipping between two equivalent chair conformers at a rate of approximately 105 times per second. These two chair conformers are in equilibrium. The rapid ring flipping results in the interconversion of the axial proton to an equatorial proton and an equatorial to the axial proton. Such interconversions are too rapid and cannot be detected on the NMR timescale. Hence, the NMR spectrometer cannot distinguish between the...
1.2K
Inductance: Solid Cylindrical Conductor01:24

Inductance: Solid Cylindrical Conductor

To calculate the inductance of a solid cylindrical conductor, consider a 1-meter section of a non-magnetic, current-carrying conductor with radius r. Disregarding end effects and assuming uniform current density, Ampere's law helps determine the magnetic field inside the conductor. This law states that the magnetic field intensity H is concentric and constant within the conductor.
Given the uniform current distribution, the magnetic field Hx and flux density Bx inside the conductor are...
777