Related Experiment Video
Updated: Dec 29, 2025

A Detailed Protocol for Perspiration Monitoring Using a Novel, Small, Wireless Device
Published on: November 24, 2016
A 0.065-mm3 Monolithically-Integrated Ultrasonic Wireless Sensing Mote for Real-Time Physiological Temperature
Abstract:
Accurate monitoring of physiological temperature is important for many biomedical applications, including monitoring of core body temperature, detecting tissue pathologies, and evaluating surgical procedures involving thermal treatment such as hyperthermia therapy and tissue ablation. Many of these applications can benefit from replacing external temperature probes with injectable wireless devices. Here we present such a device for real-time in vivo temperature monitoring that relies on "chip-as-system" integration. With an on-chip piezoelectric transducer and measuring only 380 μm × 300 μm × 570 μm, the 0.065-mm3 monolithic device, in the form of a mote, harvests ultrasound energy for power and transmits temperature data through acoustic backscattering. Containing a low-power temperature sensor implemented with a subthreshold oscillator and consuming 0.813 nW at 37 °C, the mote achieves line sensitivity of 0.088 °C/V, temperature error of +0.22/-0.28 °C, and a resolution of 0.0078 °C rms. A long-term measurement with the mote reveals an Allan deviation floor of <138.6 ppm, indicating the feasibility of using the mote for continuous physiological temperature monitoring.
Related Concept Videos
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's...
Assessing Body Temperature - Axilla
Step 1: Perform hand hygiene and put on clean gloves to maintain infection control and prevent cross-contamination.
Step 2: Prepare the patient by explaining the procedure to ensure understanding and cooperation. Ensure privacy, expose the axilla, and inform the patient that minimal movement is crucial for an accurate reading.
Step 3: Adjust the patient’s clothing to expose only the axilla. It minimizes...
Assessing Body Temperature - Tympanic membrane
Step 1: Begin by practicing good hand hygiene to prevent the transmission of microorganisms.
Step 2: Turn on the thermometer and wait until the ready sign appears on the screen to ensure accurate measurement.
Step 3: Slide the probe cover in place to prevent cross-contamination.
Step 4: Instruct the patient to tilt their head to the side for comfort and check for cerumen...
Assessing Body Temperature - Oral
Step 1:
Start by practicing proper hand hygiene to prevent the spread of microorganisms.
Step 2:
Take the thermometer out of the charging unit, switch it on, and wait for the ready sign.
Step 3:
Gently slide the probe cover until a click is heard. This simple action prevents cross-contamination and ensures the correct placement of the probe cover.
Step 4:
Instruct the patient to open their mouth and place...