Simultaneous Retrieval of the Size and Refractive Index of Suspended Droplets in a Linear Quadrupole Electrodynamic

Chelsea L Price1, Alison Bain2, Brandon J Wallace2

  • 1Department of Chemistry, University of California Riverside, Riverside, California 92420, United States.

Related Concept Videos

Mass Analyzers: Common Types01:19

Mass Analyzers: Common Types

The quadrupole mass analyzer consists of four cylindrical metal rods arranged in a diamond carrying a DC voltage and a radio-frequency AC voltage. The motion of ions through the quadrupole depends on the field strength, causing only ions of a certain m/z to resonate successfully and strike the detector at a given field strength. Though the transmission rate for these analyzers is high, the exact elemental composition of the sample is not determined because of low resolution; however, they are...
1.3K
Size-Exclusion Chromatography01:08

Size-Exclusion Chromatography

In size-exclusion chromatography (SEC), also known as molecular-exclusion or gel-permeation chromatography, molecules are separated based on their sizes. This technique is important for separating large molecules such as polymers and biomolecules. The two classes of micron-sized stationary phases encountered in SEC are silica particles and cross-linked polymer resin beads. Both materials are porous, but their pore sizes vary significantly.
Silica particles offer advantages such as rigidity,...
1.5K
Electrospray Ionization (ESI) Mass Spectrometry01:12

Electrospray Ionization (ESI) Mass Spectrometry

Higher molecular weight biomolecules are nonvolatile compounds that may decompose before ionizing or vaporizing during mass analysis with conventional electron impact ionization methods. Accordingly, electrospray ionization (ESI) is the favored method for vaporizing and ionizing biomolecules as it circumvents rapid fragmentation and enables the recording of mass signals for the entire biomolecule.
ESI utilizes electrical energy to transfer ions from the liquid phase of the sample into the...
1.9K
Mass Analyzers: Overview01:13

Mass Analyzers: Overview

The mass analyzer is a crucial component of the mass spectrometer. In the ionization chamber, the vaporized sample is bombarded with a high-energy electron beam to generate a radical cation and further fragment into neutral molecules, radicals, and cations. A series of negatively charged accelerator plates accelerate the cations into the mass analyzer. The mass analyzer separates ions according to their mass-to-charge (m/z) ratios and then directs them to the detector. The common types of mass...
1.5K