Related Experiment Video
Updated: Dec 29, 2025

Optical Clearing and Imaging of Immunolabeled Kidney Tissue
Published on: July 22, 2019
Immunoperoxidase and Immunofluorescence on Formalin-Fixed, Paraffin-Embedded Tissue Sections versus
Nasar Yousuf Alwahaibi1, Rajaa Mohammed Alsidiri1, Thuraiya Amer Alsinawi1
1Department of Allied Health Sciences, College of Medicine and Health Sciences, Sultan Qaboos University, Sultanate of Oman.
Introduction:
There are few published studies comparing immunofluorescence on formalin-fixed, paraffin-embedded (FFPE) tissue sections (IF-P) and immunoperoxidase on FFPE tissue sections (IP-P) with immunofluorescence on frozen sections (IF-F) for evaluation of renal diseases. Also, the accuracy for each method differs greatly. The aim of this study was to evaluate IF-P and IP-P as an alternative to IF-F (gold standard method) in the diagnosis of renal biopsies specimens.
Methods:
In all, 101 renal biopsies were subjected to IF-P, IP-P, and IF-F staining to demonstrate immunoglobulin IgA, IgG, and IgM immune deposits. Sensitivity, specificity, false-positive, and false-negative values were calculated.
Results:
IP-P showed sensitivity of 61.8%, 74.2%, and 64.2%, and specificity of 84.8%, 69.2%, and 66.7% for IgA, IgG, and IgM, respectively. IF-P showed a sensitivity of 45.6%, 69.4% and 52.8%, and specificity of 87.9%, 87.2% and 77.1% for IgA, IgG and IgM, respectively. False-positive cases of IF-P and IP-P were 4, 5, and 11 and 5, 12, and 16 for IgA, IgG, and IgM, respectively.
Conclusion:
Where IF-F lacks glomeruli or fresh renal biopsies are not available, IP-P is a sensitive method, whereas IF-P is a specific method for the evaluation of immune deposits in the renal tissue biopsies. The presence of false-positive cases in both methods deserves further research.