Spleen size improvement in advanced heart failure patients using a left ventricular assist device
Hiroaki Hiraiwa1, Takahiro Okumura1, Akinori Sawamura2
1Department of Cardiology, Nagoya University Graduate School of Medicine, Nagoya, Japan.
Abstract:
The spleen has been recognized as an important organ that holds a reserve of 20% to 30% of the total blood volume. Spleen contraction and splenic volume reduction occur in patients with hypovolemic shock. However, the change in the spleen volume and the association between spleen size and hemodynamic parameters remain unclear in patients with advanced heart failure (HF) who need left ventricular assist device (LVAD) support. This study was performed to investigate the change in spleen size and the relationship between spleen size and hemodynamic parameters before and after LVAD implantation in patients with advanced HF. We enrolled 20 patients with advanced HF on LVAD support. All patients underwent right heart catheterization and computed tomography before and after LVAD implantation. The spleen size was measured by computed tomography volumetry. We excluded patients with a mean right atrial pressure (RAP) of <5 mm Hg because of the possibility of hypovolemia and those with a cardiac index of >2.2 L/min/m2 before LVAD implantation. The splenic volume significantly increased from 160.6 ± 46.9 mL before LVAD implantation to 224.6 ± 73.5 mL after LVAD implantation (P < .001). Before LVAD implantation, there was a significant negative correlation between spleen volume and systemic vascular resistance (SVR). After LVAD implantation, however, there were significant correlations between spleen volume and the cardiac index, RAP, and pulmonary capillary wedge pressure despite the absence of a significant correlation between spleen volume and SVR. Furthermore, one patient developed reworsening HF because of LVAD failure due to pump thrombosis. In this case, the splenic volume was 212 mL before LVAD implantation and increased to 418 mL after LVAD implantation, although it decreased to 227 mL after LVAD failure. The spleen size may change depending on hemodynamics in patients with advanced HF with LVAD support, reflecting sympathetic nerve activity and the systemic volume status.
More Related Videos
08:04A Mouse Model of Vascularized Heterotopic Spleen Transplantation for Studying Spleen Cell Biology and Transplant Immunity
Published on: June 11, 2019
08:49Author Spotlight: Enhancing Graft Viability Assessment Through Quantitative Metrics and Innovative Reservoir Systems
Published on: August 2, 2024
Related Concept Videos
Heart Failure VI: Adjunct Therapies
Cardiomyopathy V: Interprofessional Care
Cardiomyopathy II: Dilated Cardiomyopathy
Heart Failure V: Medical Management
Heart Failure II: Pathophysiology