Abstract:
Dental ceramics because of their translucency exemplify the most biologically realistic restorative materials for aesthetic rehabilitation and can be used to estimate dose accumulated as a result of a nuclear accident or attack. In this study, lithium disilicate ceramic obtained from Vivadent Ivoclar, Turkey was studied for its thermoluminescence (TL) properties. The lithium disilicate glass ceramic was irradiated with a 90 Sr-90 Y β-source from 10 Gy to 6.9 kGy and the results read on a Harshaw 3500 reader. The TL peak of lithium disilicate ceramic showed sublinearity in the range 12 Gy to 6 kGy. The area under the TL glow curve increased by about 25% by the end of 10th measurement cycle. Fading values were also considered after irradiation. Lithium disilicate ceramic samples underwent 37% fading after 1 h and 59% fading after 1 week. In addition to the experimental study, a software-based simulation study was also undertaken using a MATLAB system identification tool. Experimental studies are generally time consuming and some materials used for experiments are very expensive. In this study, experimental, and simulation results were compared and produced almost the same outcome with a similarity of more than 98%.
More Related Videos
06:48Fluid-cell Raman Spectroscopy for operando Studies of Reaction and Transport Phenomena during Silicate Glass Corrosion
Published on: May 9, 2025
06:06A Simple Dewar/Cryostat for Thermally Equilibrating Samples at Known Temperatures for Accurate Cryogenic Luminescence Measurements
Published on: July 19, 2016
Related Concept Videos
Linear Approximation in Frequency Domain
In contrast, nonlinear systems do not inherently possess these properties. However, for small deviations around an operating point, a nonlinear system can often be approximated as linear....
Linear time-invariant Systems
The input-output behavior of an LTI system can be fully defined by its response to an impulsive excitation at its input. Once this impulse response is known, the system's reaction to any other input can be...
Series RLC Circuit with Source
In this context, the input DC voltage serves as a forcing step function, resulting in a forced step response that mirrors the characteristics of the input. Applying Kirchhoff's voltage law to the circuit yields a...