Related Experiment Video
Updated: Dec 29, 2025

Home-Based Prescribed Pulmonary Exercise in Patients with Stable Chronic Obstructive Pulmonary Disease
Published on: August 24, 2019
Relationships Between Forced Oscillatory Impedance and 6-minute Walk Distance After Pulmonary Rehabilitation in COPD
Sabine C Zimmermann1,2,3, Cindy Thamrin1, Andrew Sl Chan2,3
1The Woolcock Emphysema Centre, Woolcock Institute of Medical Research, The University of Sydney, Glebe, NSW 2037, Australia.
Rationale:
Pulmonary rehabilitation for chronic obstructive pulmonary disease (COPD) reduces dyspnoea and improves exercise capacity and quality of life. The improvement in exercise capacity is variable and unpredictable, however. Respiratory system impedance obtained by forced oscillation technique (FOT) as a measure of ventilatory impairment in COPD may relate to improvement in exercise capacity with pulmonary rehabilitation. We aimed to determine if baseline FOT parameters relate to changes in exercise capacity following pulmonary rehabilitation.
Methods:
At the start of rehabilitation, 15 COPD subjects (mean(SD) 75.2(6.1) years, FEV1 z-score -2.61(0.84)) had measurements by FOT, spirometry, plethysmographic lung volumes and 6-minute walk distance (6MWD). Respiratory system resistance (Rrs) and reactance (Xrs) parameters as the mean over all breaths (Rmean, Xmean), during inspiration only (Rinsp, Xinsp), and expiratory flow limitation (DeltaXrs = Xinsp-Xexp), were calculated. FOT and 6MWD measurements were repeated at completion of rehabilitation and 3 months after completion.
Results:
At baseline, Xrs measures were unrelated to 6MWD. Xinsp improved significantly with rehabilitation (from mean(SD) -2.35(1.02) to -2.04(0.85) cmH2O.s.L-1, p=0.008), while other FOT parameters did not. No FOT parameters related to the change in 6MWD at program completion. Baseline Xmean, DeltaXrs, and FVC z-score correlated with the change in 6MWD between completion and 3 months after completion of rehabilitation (rs=0.62, p=0.03; rs=-0.65, p=0.02; and rs=0.62, p=0.03, respectively); with worse ventilatory impairment predicting loss of 6MWD. There were no relationships between Rrs parameters, FEV1 or FEV1/FVC z-scores and changes in 6MWD.
Conclusion:
Baseline reactance parameters may be helpful in predicting those patients with COPD at most risk of loss of exercise capacity following completion of pulmonary rehabilitation.
Related Concept Videos
Chronic Obstructive Pulmonary Disease-II: Pathophysiology
Chronic Inflammation
Pulmonary Function Tests
Pulmonary Function Tests are crucial diagnostic tools for assessing respiratory function, particularly in patients with chronic respiratory disorders. They comprehensively evaluate lung volumes, ventilatory function, breathing mechanics, diffusion, and gas exchange. These tests help diagnose pulmonary diseases and play a significant role in monitoring disease progression, evaluating disability, and assessing response to therapy.
PFTs involve using a spirometer, a...
Chronic Obstructive Pulmonary Disease-IV: Assessement and Diagnostic Studies
Medical History
Chronic Obstructive Pulmonary Disease
Smoking is a primary risk factor for COPD, with over 80% of patients having a history of it. Patients typically experience progressive dyspnea or labored breathing, frequent coughing, and recurrent pulmonary infections. Many eventually succumb to respiratory failure, characterized by...
Chronic Obstructive Pulmonary Disease-I: Introduction
COPD: Management Using Bronchodilators and Corticosteroids

