Related Experiment Video
Updated: Dec 29, 2025

Vascularized Composite Hand Allograft Procurement and Preparation for Distal and Proximal Forearm Allotransplantation: A Stepwise Approach
Published on: May 23, 2025
Contact Pressure between Digital Flexors and Plates for Distal Radius Approaches
Christopher M Jones1, Roshan Melvani1, Keith T Aziz1
1Curtis National Hand Center, MedStar Union Memorial Hospital, Baltimore, Maryland.
Abstract:
Background Flexor tendon irritation or rupture following open reduction and volar plate fixation of distal radius fractures can cause significant morbidity and necessitate additional surgical intervention. Objectives To compare the impact of the extended flexor carpi radialis (e-FCR) and standard flexor carpi radialis (FCR) approaches on contact pressures between the flexor tendons and volar distal radius plates. Methods Eight matched pairs of fresh frozen cadavers had each limb randomized to undergo either the e-FCR or standard FCR approach. After the approach, a locking plate was applied to the volar distal radius more distally than ideally to create a worst-case scenario for the digital flexor tendons. Electronic pressure sensors were secured to the volar aspect of each locking plate. Each wrist was pinned in 20 degrees of extension during testing. Using a computer-controlled stepper motor system attached to the digital flexor and extensor tendons, the digits were taken through 4,000 cycles simulating 12 weeks of active flexion and extension. Results There were no statistically or clinically significant differences when comparing the contact pressures of the e-FCR approach with the standard FCR approach at any time intervals. The e-FCR had statistically significantly higher radial-sided contact pressures than ulnar-sided contact pressures during early-to-intermediate testing intervals. These differences resolved at late and final testing intervals. Conclusions When comparing the standard FCR approach with the e-FCR approach, with the wrist in 20 degrees of extension, there is no significant difference in contact pressures that occur between the digital flexor tendons and volar distal radius plates. Clinical Relevance Further study and technique modifications may eventually lead to better methods of avoiding flexor tendon rupture during the volar plating of distal radius fractures.
More Related Videos
07:33In Vitro Application of a Wireless Sensor in Flexion-Extension Gap Balance of Unicompartmental Knee Arthroplasty
Published on: May 5, 2023
05:18Author Spotlight: Ultrasound-Guided Needle Release Combined with Corticosteroid Injection for the Treatment of Supinator Syndrome
Published on: May 26, 2023
Related Concept Videos
Bones of the Upper Limb: Radius
The radius has a nail-shaped head, and a...
Muscles of the Forearm that Move the Hand and Fingers
Anterior Compartment
The anterior compartment muscles originate from the humerus. They primarily function as flexors and are also known as flexor muscles. They typically insert on the carpals, metacarpals, and phalanges. The superficial layer includes the flexor carpi...
Bones of the Upper Limb: Ulna
Bearings: Problem Solving
Muscles that Move the Forearm
Forearm Flexors
The biceps brachii, brachialis, and brachioradialis are forearm flexors. The biceps brachii is made up of two heads. Its long head originates at the supraglenoid tubercle of the scapula, whereas that of the short head is...
Fluid Pressure over Flat Plate of Variable Width
The pressure distribution on the plate can be calculated by determining the force that acts on a differential area strip of the plate. Thus, the magnitude of the force is equal to the...