Using the Bair Hugger™ temperature monitoring system in neck and chest regions: a pilot study
Shunsuke Tachibana1, Yutaro Chida2, Michiaki Yamakage2
1Department of Anesthesiology, Sapporo Medical University, School of Medicine, Sapporo, South 1, West 16, Chuo-ku, Sapporo, Hokkaido, 060-8543, Japan. shunsuke.tachibana@gmail.com.
Purpose:
Temperature monitoring in the perioperative periods is important in order to avoid both hyperthermia and hypothermia. In our pilot study, we evaluated the usefulness of Bair Hugger™ temperature monitoring system (BHTMS), a forehead deep temperature monitoring system, in the neck and chest under general anesthesia.
Methods:
After approval from the Sapporo Medical University Research Ethics Board, 30 female patients scheduled for laparoscopic surgery were enrolled in this study. Patients were divided into three groups, depending on the attachment regions of BHTMS sensor. Temperatures obtained from the three regions and each esophageal temperature (TEso) were monitored and analyzed.
Results:
A Bland-Altman plot showed that the mean bias between temperature obtained from the neck and TEso was + 0.05 °C above TEso (2SD ± 0.35 °C), and that between temperature obtained from the chest and TEso was - 0.55 °C above TEso (2SD ± 0.55 °C).
Conclusion:
By using the BHTMS sensor in the neck region, it is possible to monitor core body temperature seamlessly and with high reliability. These results may suggest that the use of BHTMS has high versatility in measuring perioperative core body temperature.
Trial Registration:
This study was approved by the Sapporo Medical University Research Ethics Board (2015: No. 262-149) and registered with UMIN Clinical Trial Registry ( UMIN000016802 Registered 15 March 2015).
More Related Videos
04:54Using a Combination of Indirect Calorimetry, Infrared Thermography, and Blood Glucose Levels to Measure Brown Adipose Tissue Thermogenesis in Humans
Published on: June 2, 2023
04:34Mouse Body Temperature Measurement Using Infrared Thermometer During Passive Systemic Anaphylaxis and Food Allergy Evaluation
Published on: September 14, 2018
Related Concept Videos
Assessing Body Temperature - Axilla
Step 1: Perform hand hygiene and put on clean gloves to maintain infection control and prevent cross-contamination.
Step 2: Prepare the patient by explaining the procedure to ensure understanding and cooperation. Ensure privacy, expose the axilla, and inform the patient that minimal movement is crucial for an accurate reading.
Step 3: Adjust the patient’s clothing to expose only the axilla. It minimizes...
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's...
Assessing Body Temperature - Rectal
Follow these steps for rectal temperature assessment:
Step 1: Perform hand hygiene and don clean gloves to prevent cross-infection.
Step 2: Position the patient in a side-lying position to better visualize the rectal...
Assessing Body Temperature - Oral
Step 1:
Start by practicing proper hand hygiene to prevent the spread of microorganisms.
Step 2:
Take the thermometer out of the charging unit, switch it on, and wait for the ready sign.
Step 3:
Gently slide the probe cover until a click is heard. This simple action prevents cross-contamination and ensures the correct placement of the probe cover.
Step 4:
Instruct the patient to open their mouth and place...
Assessing Body Temperature - Tympanic membrane
Step 1: Begin by practicing good hand hygiene to prevent the transmission of microorganisms.
Step 2: Turn on the thermometer and wait until the ready sign appears on the screen to ensure accurate measurement.
Step 3: Slide the probe cover in place to prevent cross-contamination.
Step 4: Instruct the patient to tilt their head to the side for comfort and check for cerumen...