Body Positional Effects on Bioimpedance Spectroscopy Measurements for Lymphedema Assessment of the Arm
Related Experiment Video
Updated: Dec 29, 2025

Ultrasonographic Evaluation of Breast Cancer-related Lymphedema
Published on: January 12, 2017
Louise A Koelmeyer1, Leigh C Ward2, Catherine Dean3
1Australian Lymphoedema Education, Research and Treatment Program, Department of Clinical Medicine, Faculty of Medicine and Health Sciences, Macquarie University, Sydney, Australia.
Abstract:
Bioimpedance spectroscopy (BIS) measurements have conventionally been performed using a device that uses gel-backed electrodes with the patient in a supine position. More recently, impedance devices that use stainless steel electrodes with the patient in a standing position have become available. The aim of this study was to assess and compare BIS measurements made in three different body positions using two different impedance devices (lead device and stand-on device) in women with and without arm lymphedema. A cross-sectional study design was used to recruit two cohorts of women, healthy controls (n = 47) and those who had been diagnosed with breast cancer (n = 53) and were either at risk of (n = 14) or with unilateral arm lymphedema (n = 39). BIS measurements were taken three times in each position for each device. Impedance measurements were reliably made using either a lead or stand-on device with a coefficient of variation being 0.6% or lower. Absolute impedance measurements for the stand-on device were larger than the comparable lead device values due to the difference in electrode position, but were highly correlated (r = 0.92, p < 0.0001). Interarm impedance ratios and L-Dex scores were slightly (3.1% equivalence), but significantly different. The findings support impedance measurements being made reliably using either the lead or stand-on device, representing supine and upright measurement positions, respectively. Data between devices were, however, not directly interchangeable.
More Related Videos
06:03Integrating Augmented Reality Tools in Breast Cancer Related Lymphedema Prognostication and Diagnosis
Published on: February 6, 2020
10:21Evaluation of Hydration Status by Bioelectrical Impedance Vector Analysis in Patients with Ischemic Heart Disease Undergoing Exercise Stress Test
Published on: September 22, 2023
Related Concept Videos
Pre-Procedural Guidelines for Assessing Blood Pressure
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above...
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Sites for measruring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement