Related Experiment Video
Updated: Aug 11, 2026

Dosimetry for Cell Irradiation using Orthovoltage 40-300 kV X-Ray Facilities
Published on: February 20, 2021
A practical method for quantifying dose in bone and lung using TLDs when using 6 and 15 MV photon beams
Neslihan Sarigul1,2, Murat Surucu3,2, Chester Reft4
1Institute of Nuclear Science, Hacettepe University, 06532 Ankara, Turkey.
Abstract:
This paper presents a practical method for converting dose measured with thermoluminescent dosimeters (TLD) to dose in lung and bone for 6 MV and 15 MV photon beams. Monte Carlo (MC) simulations and Burlin cavity theory calculations were performed to calculate [Formula: see text], the dose-to-TLD to dose-to-medium conversion factor. A practical method was proposed for converting TLD-measured-dose to dose-in-medium using the TLD dose calibration in water and [Formula: see text] dose-to-medium to dose-to-water conversion factor. Theoretical calculations for [Formula: see text] were performed using photon spectrum weighted parameters and were compared with MC simulations. Verification of the proposed method was done using phantoms having either bone or lung equivalent slabs stacked in between solid water slabs. Percent depth dose (PDD) curves were measured using 0.089 cm thick LiF:Mg,Ti (TLD-100) dosemeters placed at various depths within these phantoms. They were then corrected with [Formula: see text] factors using the proposed dose conversion method, and were compared with the MC simulations. For 6 MV beam, the MC calculated [Formula: see text] factors were 0.942 and 1.002 for bone and lung, and for 15 MV it was 0.927 and 1.005 for bone and lung, respectively. The difference between the MC simulated and spectrum weighted theoretical [Formula: see text] factors were within 3% for both lung and bone. The PDD curves measured with TLD-100 chips that were corrected using the proposed method agreed well within 1.5% of the MC simulated PDD curves for both the water/lung/water and water/bone/water (WBW) phantoms. The dose-to-medium correction using MC simulated [Formula: see text] is convenient, easy, and accurate. Therefore, it can be used instead of Burlin cavity theory, especially in media with high atomic numbers such as bone for accurate dose quantification.
More Related Videos
06:20Irradiator Commissioning and Dosimetry for Assessment of LQ α and β Parameters, Radiation Dosing Schema, and in vivo Dose Deposition
Published on: March 11, 2021
07:57Positron Emission Tomography-based Dose Painting Radiation Therapy in a Glioblastoma Rat Model using the Small Animal Radiation Research Platform
Published on: March 24, 2022