Phase I clinical study with different doses of 99mTc-TRODAT-1 in healthy adults
Yu Sun1, Zhengping Chen2, Congjin Liu1
1Department of Nuclear Medicine, Huashan Hospital, Fudan University, No. 12 Wulumuqi Middle Road, Jing'an District, Shanghai, 200040, China.
Objectives:
To study the pharmacokinetics, biodistribution, and injection doses of 99mTc-TRODAT-1 in healthy adults.
Methods:
Thirty healthy individuals comprising 15 females and 15 males were randomly divided into three groups and the injection doses of 99mTc-TRODAT-1 of group 1, 2, and 3 were 370 MBq, 740 MBq, and 1110 MBq, respectively. Assessments of subjective symptoms and tests were performed before and after injection. Blood and urine collections and whole-body planar imaging were analyzed at various time points. Bilateral brain striatal SPECT images obtained at 3.5 h PI were assessed visually and semiquantitatively.
Results:
No serious adverse events or deaths were observed in our study. The pharmacokinetic analysis showed that 99mTc-TRODAT-1 was eliminated rapidly from the circulation, with just about 4% of the injected dose remaining in blood at 1 h post-injection. The mean cumulative urinary excretion over 24 h was just 2.96 ± 0.96%ID. The time-activity curve demonstrated that the radioactivity was mainly in liver and abdomen. The highest absorbed dose was in the dose-limiting organ, liver (20.88 ± 4.45 × 10-3 mSv/MBq). The average effective dose was 5.22 ± 1.05 × 10-3 mSv/MBq. The clarity of striatal images assessed visually in group 1 was worse than that in group 2 and 3. The semiquantitative analysis showed that there were no differences in striatum/cerebellum between the three groups (group 1: 1.77 ± 0.11, group 2: 1.62 ± 0.14, and group 3: 1.75 ± 0.20; P = 0.088).
Conclusions:
99mTc-TRODAT-1 was safe to use in humans and showed the status of dopaminergic neurons specifically and clearly. The injection dose we suggested was 740 MBq.
More Related Videos
10:54Preparation and Evaluation of 99mTc-labeled Tridentate Chelates for Pre-targeting Using Bioorthogonal Chemistry
Published on: February 4, 2017
09:49A Whole Body Dosimetry Protocol for Peptide-Receptor Radionuclide Therapy PRRT: 2D Planar Image and Hybrid 2D+3D SPECT/CT Image Methods
Published on: April 24, 2020
Related Concept Videos
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Bioavailability Study Design: Healthy Subjects Versus Patients
Clinical Trials: Overview
Clinical Trials
There are four phases in a clinical trial. A phase one...
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...