Related Experiment Video
Updated: Dec 29, 2025

Effects of Surgical Masks on Cardiopulmonary Function in Healthy Subjects
Published on: February 12, 2021
Exercise in Thermal Inversions: PM2.5 Air Pollution Effects on Pulmonary Function and Aerobic Performance
Dale R Wagner1, Daniel C Brandley1
1Kinesiology & Health Science Department, Utah State University, Logan, UT.
Introduction:
Wintertime thermal inversions can lead to the accumulation of small particulate matter (PM2.5). Despite an association between respiratory hospital admissions and elevated PM2.5 levels, many people continue to exercise outdoors during inversions. This study compared pulmonary function and exercise performance during periods of low and high ambient PM2.5 concentrations.
Methods:
Forced vital capacity and forced expiratory volume in 1 s were measured outdoors before and after two 3200 m running time trials: one with low ambient PM2.5 (0.6-14.7 microgram·m-3), and the other during high PM2.5 (19.1-42.5 micrograms·m-3). A 10 cm visual analog scale (VAS) administered postexercise quantified subjective ratings of respiratory discomfort.
Results:
The PM2.5 differential between trials was ≥18 micrograms·m-3 for 10 healthy runners. Despite feeling more respiratory discomfort (P=0.044) during the bad air trial (VAS: 4.6±1.8 cm) compared with the good air trial (VAS: 2.9±1.8 cm), the 3200 m run time (low PM2.5: 13:54±1:34 min:s; high PM2.5: 14:07±1:44 min:s) was not different (P=0.261) between trials. Postexercise forced vital capacity was not significantly different (P=0.846) between the low (4.86±1.00 L) and high (4.84±0.95 L) PM2.5 conditions. Similarly, the difference in postexercise forced expiratory volume in 1 s was not significant (P=0.750) between trials (4.22±0.89 L vs 4.23±0.85 L).
Conclusions:
Neither run time nor pulmonary function of healthy adults were adversely affected by an acute bout of exercise in elevated ambient PM2.5, equivalent to yellow or orange on the air quality index.
Related Concept Videos
Factors Affecting Pulmonary Ventilation
Alveolar Surface Tension
The alveolar fluid lines the luminal surface of the alveoli and exerts a force called surface tension. This force is caused by the polar water molecules in the liquid being more strongly attracted to each...
Factors Affecting Respiration
Hyperpnea and Hyperventilation
Acute Respiratory Failure-II
The underlying physiological abnormalities that contribute to hypoxemic respiratory failure include:
Chronic Obstructive Pulmonary Disease-II: Pathophysiology
Chronic Inflammation
Respiratory Capacities
One key metric is the Inspiratory Capacity (IC), which represents the maximum amount of air that can be inhaled with full effort. IC is calculated by summing the tidal volume and inspiratory reserve volume, typically ranging from 2.4 to 3.6 liters.
The Functional Residual Capacity (FRC) represents the air in the...

