Related Experiment Video
Updated: Dec 29, 2025

Ice Generation and the Heat and Mass Transfer Phenomena of Introducing Water to a Cold Bath of Brine
Published on: March 13, 2017
Assessing the Impact of a Heated Basement on Groundwater Temperatures in Bratislava, Slovakia
David Krcmar1, Renata Flakova1, Ivana Ondrejkova1
1Comenius University, Faculty of Natural Sciences, Department of Hydrogeology, Comenius University, Ilkovicova 6, 842 15, Bratislava, Slovakia.
Abstract:
Groundwater temperature is a useful hydrogeological parameter that is easy to measure and can provide much insight into groundwater flow systems, but can be difficult to interpret. For measuring temperature directly in the ground, dedicated specifically designed monitoring wells are recommended since conventional groundwater wells are not optimal for temperature monitoring. Multilevel monitoring of groundwater temperature is required to identify contributions of different possible heat inputs (sources) on measured temperature signals. Interpreting temperature data as a cosine function, including period, average temperature, amplitude, and phase offset, is helpful. Amplitude dampening and increasing phase shift with distance from a boundary can be used for estimation of transport parameters. Temperature measurements at different depths can be used for evaluation of unknown parameters of analytical functions by optimization of regression fits in Python. These estimated parameters can be used to calculate temperatures at known water table depths which can be applied as a fixed transient boundary condition in MT3DMS to overcome the limitations of MT3DMS heat transport modeling in the unsaturated zone. In this study, temperature monitoring and modeling was used to evaluate the influence of a department store's heated basement foundation on groundwater temperature within a green space (city park), with the main outcome that 17 years after construction, the department store foundation has increased the mean groundwater temperature by 3.2 °C. Heat input evaluated by the MT3DMS model varied from 0.1 W/m2 at a distance of 100 m up to 12 W/m2 next to the building.
Related Concept Videos
Thermal Expansion
Hot Weather Concreting
Mitigating the heat increase in concrete can be economically achieved by shading aggregate stockpiles to prevent heating from solar radiation,...
Cold Weather Concreting
To counteract the negative impacts of cold weather, ensuring...
Effect of Sea Water on Concrete
Concrete in areas between tide marks,...
Masonry in Cold and Hot Weather Conditions
Other key practices include keeping masonry units...
Design Example: Managing Concrete Workability

