Related Experiment Video
Updated: Dec 29, 2025

Author Spotlight: Advancing Awake Nasotracheal Intubation with Flexible Video Rhino-Laryngoscopes
Published on: August 2, 2024
LMA Gastro™ airway is feasible during upper gastrointestinal interventional endoscopic procedures in high risk
Axel Schmutz1, Thomas Loeffler2, Arthur Schmidt3
1Department of Anesthesiology and Critical Care, Faculty of Medicine, Medical Center - University of Freiburg, University of Freiburg, Hugstetter Strasse 55, 79106, Freiburg im Breisgau, Germany. axel.schmutz@uniklinik-freiburg.de.
Background:
Nonoperating room anesthesia during gastroenterological procedures is a growing field in anesthetic practice. While the numbers of patients with severe comorbidities are rising constantly, gastrointestinal endoscopic interventions are moving closer to minimally invasive endoscopic surgery. The LMA Gastro™ is a new supraglottic airway device, developed specifically for upper gastrointestinal endoscopy and interventions. The aim of this study was to evaluate the feasibility of LMA Gastro™ in patients with ASA physical status ≥3 undergoing advanced endoscopic procedures.
Methods:
We analyzed data from 214 patients retrospectively who received anesthesia for gastroenterological interventions. Inclusion criteria were upper gastrointestinal endoscopic interventions, airway management with LMA Gastro™ and ASA status ≥3. The primary outcome measure was successful use of LMA Gastro™ for airway management and endoscopic intervention.
Results:
Thirtyone patients with ASA physical status ≥3, undergoing complex and prolonged upper gastrointestinal endoscopic procedures were included. There were 7 endoscopic retrograde cholangiopancreatographies, 7 peroral endoscopic myotomies, 5 percutaneous endoscopic gastrostomies and 12 other complex procedures (e.g. endoscopic submucosal dissection, esophageal stent placement etc.). Of these, 27 patients were managed successfully using the LMA Gastro™. Placement of the LMA Gastro™ was reported as easy. Positive pressure ventilation was performed without difficulty. The feasibility of the LMA Gastro™ for endoscopic intervention was rated excellent by the endoscopists. In four patients, placement or ventilation with LMA Gastro™ was not possible.
Conclusions:
We demonstrated the feasibility of the LMA Gastro™ during general anesthesia for advanced endoscopic procedures in high-risk patients.
Trial Registration:
German Clinical Trials Register (DRKS00017396) Date of registration: 23rd May 2019, retrospectively registered.
Related Concept Videos
Endoscopic Procedures I: Esophagogastroduodenoscopy
During an EGD, the endoscope can be used to:
Cardiopulmonary Resuscitation V: Advanced Airway Management Techniques
Endoscopic Procedures IV: Sigmoidoscopy and Laproscopy
Sigmoidoscopy
Sigmoidoscopy is a diagnostic procedure that uses a flexible sigmoidoscope equipped with a light source and camera to examine the rectum and sigmoid colon. The procedure involves inserting the tube through the anus...
Endoscopic Studies I: Bronchoscopy and Thoracoscopy
Bronchoscopy
Description
Bronchoscopy is a procedure that involves direct visualization of the larynx, trachea, and bronchi for diagnostic and therapeutic purposes. A flexible fiber optic or rigid bronchoscope is used to carry out the procedure. The fiber-optic bronchoscope is more frequently used due...
Endoscopic Procedures V: ERCP
Patient...