Related Experiment Video
Updated: Dec 29, 2025

Author Spotlight: Microbial Control and Monitoring Strategies for Cleanroom Environments and Cellular Therapies
Published on: March 17, 2023
[Reevaluating the shelf life of sterilized packaged items via a risk-analysis study]
L Tourvieilhe1, A Guillermet1, H Hida1
1Unité de stérilisation, service pharmacie, centre hospitalier de Valence, 179, boulevard du Maréchal Juin, 26953 Valence cedex 9, France.
Abstract:
In the hospital, all the reprocessed reusable medical devices (RMD) are conditioned with a sterile barrier system and a protection package and they expire after three months. The objective of this study is to reevaluate this shelf life via a risk-analysis study focusing on the steps whose malfunction can fail RMD sterility. The first step is analysing current conditions of packaging, transportation and storage of RMD. The risk-analysis study has been built on French National Authority for Health template. Risks are prioritized in three categories: non critical risks, risks that need to be kept track of and risks to manage as a priority. Storage conditions have been evaluated in 52 wards in ten different structures. All of the wards respect the paper side of the pouches. They were stored in a dedicated storage unit in 85 % of the units. They were closed at the moment of the observation in 58 % of the cases. RMD were stacked in 81 % of the units and 36 % of them had at leat one expired RMD in their storage unit. The risk-analysis study identified two risks to manage as a priority. Some RMD were damaged during transportation to a subcontractor hospital. This step is barely manageable due to the human factor but the transport rules have been reminded in order to lower the risks on the materials. The operating rooms common storage include shelves that alter pouches and wraps, but a replacement of equipments is under discussion. Thanks to a better understanding of RMD circuit current conditions, allowing a better control of sensitive steps, their shelf life is reevaluated up to 6 months for containers and 4 months for other pouches.
Related Concept Videos
Drug Product Stability
Types of Biopharmaceutical Studies: Controlled and Non-Controlled Approaches
Non-controlled studies, commonly employed for initial exploration, lack a control group, rendering them susceptible to biases and external influences. In contrast,...
Cleaning, Sterilization, and Disinfection
Cleaning
The cleaning process usually involves using water with detergents or enzymatic cleaner and removing foreign material from objects and surfaces, including organic material such as body fluids or inorganic material like soil. Cleaning is performed before high-level disinfection and sterilization because foreign materials on the cover of the devices interfere with process...
Methods of Sterilization I: Physical Methods
Steam sterilization uses non-toxic, low-cost moist heat in the form of saturated steam under pressure, which is fast, microbicidal, and sporicidal, and quickly warms and penetrates fabrics. Autoclaves, or steam sterilizers, expose each item to direct steam contact for a predetermined time at the necessary...
Methods of Sterilization II: Chemical Methods
Using chemical sterilization rather than heat to clean out equipment is recommended. It eradicates and removes all bacteria,...
Key Techniques in Microbiology