Lars Grønlykke1, Etienne J Couture2, Francois Haddad3
1Department of Cardiothoracic Anaesthesia, Rigshospitalet, Copenhagen University Hospital, Copenhagen, Denmark.
Objectives:
Right ventricular (RV) dysfunction in cardiac surgery is associated with increased mortality and morbidity and difficult separation from cardiopulmonary bypass (DSB). The primary objective of the present study was to describe the prevalence and characteristics of patients with abnormal RV diastolic pressure gradient (PG). The secondary objective was to explore the association among abnormal diastolic PG and DSB, postoperative complications, high central venous pressure (CVP), and high RV end-diastolic pressure (RVEDP).
Design:
Retrospective and prospective validation study.
Setting:
Tertiary care cardiac institute.
Participants:
Cardiac surgical patients (n=374) from a retrospective analysis (n=259) and a prospective validation group (n=115).
Intervention:
RV pressure waveforms were obtained using a pulmonary artery catheter with a pacing port opened at 19 cm distal to the tip of the catheter. Abnormal RV diastolic PG was defined as >4 mmHg. Both elevated RVEDP and high CVP were defined as >16 mmHg.
Measurements And Main Results:
From the retrospective and validation cohorts, 42.5% and 48% of the patients had abnormal RV diastolic PG before cardiac surgery, respectively. Abnormal RV diastolic PG before cardiac surgery was associated with higher EuroSCORE II (odds ratio 2.29 [1.10-4.80] v 1.62 [1.10-3.04]; p = 0.041), abnormal hepatic venous flow (45% v 29%; p = 0.038), higher body mass index (28.9 [25.5-32.5] v 27.0 [24.9-30.5]; p = 0.022), pulmonary hypertension (48% v 37%; p = 0.005), and more frequent DSB (32% v 19%; p = 0.023). However, RV diastolic PG was not an independent predictor of DSB, whereas RVEDP (odds ratio 1.67 [1.09-2.55]; p = 0.018) was independently associated with DSB. In addition, RV pressure monitoring indices were superior to CVP in predicting DSB.
Conclusion:
Abnormal RV diastolic PG is common before cardiac surgery and is associated with a higher proportion of known preoperative risk factors. However, an abnormal RV diastolic PG gradient is not an independent predictor of DSB in contrast to RVEDP.
More Related Videos
04:54Invasive Hemodynamic Assessment for the Right Ventricular System and Hypoxia-Induced Pulmonary Arterial Hypertension in Mice
Published on: October 24, 2019
08:49Author Spotlight: Enhancing Graft Viability Assessment Through Quantitative Metrics and Innovative Reservoir Systems
Published on: August 2, 2024
Related Concept Videos
Cardiomyopathy VII: Pre and Post Operative Nursing Management
Cardiac Catheterization II: Right Heart Catheterization