Transseptal puncture without fluoroscopy using a radiofrequency needle: A case series
Guram Imnadze1,2, Tarek Ajaj3, Hendrik Bante3
1Arrhythmia Department, Klinikum Osnabrueck, Germany. imnadze@web.de.
Background:
The non-fluoroscopy approach with the use of a three-dimensional (3D) navigation system is increasingly recognized as a future technology in the treatment of arrhythmias. However, there are a limited number of articles published concerning transseptal puncture without the use of fluoroscopy.
Methods:
Presented in this paper is the first series of patients (n = 10) that have undergone transseptal puncture without the use of fluoroscopy under transesophageal echocardiography control using a radiofrequency transseptal needle and a 3D navigation system.
Results:
All patients were treated without complications. In 6 patients, re-pulmonary vein isolation was performed. In 5 cases, linear ablation of the left atrium for treatment of left atrial macro re-entry tachycardia was provided. In 2 patients, focal atrial tachycardia was treated, 1 patient underwent cavo tricuspidal isthmus (CTI) ablation and 1 patient, re-CTI ablation. The ablation of complex fragmented atrial electrograms was done in 2 patients. In 1 case, right atrial macro re-entry tachycardia was treated.
Conclusions:
Transseptal puncture without using fluoroscopy is safe and effective when using a radiofrequency needle, a 3D navigation system and transesophageal echocardiography.